Rugged, compact and always reliable, the Fluke 1507 is a high accuracy insulation resistance tester with several advanced functions.
The Fluke 1507's insulation resistance mode allows the user to select between test voltages of 50, 100, 250, 500 and 1000V, giving the tester overall measurement range of 0.01MΩ to 10GΩ. Carrying out repetitive tests? The 1507 includes a Compare (PASS/FAIL) function for quicker and easier measurements.
This insulation tester is also packed full of additional features, including automatic calculation of polarisation index and dielectric absorption ratio, live circuit detection, auto capacitive voltage discharge, AC/DC voltage measurements from 0.1 to 600V and a built-in continuity testing function.
Fluke 1507 Insulation Tester Key Features
- Insulation test range from 0.01MΩ to 10GΩ
- Test voltages of 50V, 100V, 250V, 500V and 1000V
- Automatic calculation of polarisation index and dielectric absorption ratio
- Compare (PASS/FAIL) function for repetitive tests
- Includes remote probe for hard-to-reach testing applications
- Live circuit detection - prevents insulation test if voltages above 30V are detected
- Auto discharge of capacitive voltage
- AC/DC voltage measurements from 0.1V to 600V
- 200mA continuity test
- Resistance measurements from 0.01Ω to 20kΩ
- Auto power off switches the meter off when left idle
- Large-size backlit LCD display
- CAT IV 600V overvoltage rating
- Powered by 4x AA alkaline batteries
- Includes Fluke's 1 year warranty
What's Included?
- Fluke 1507 Insulation Tester
- Remote Probe
- Test Leads
- Test Probes
- Alligator Clips
- User Documentation
Fluke 1507 Technical Specifications
AC/DC Voltage Measurements | |
---|---|
Range | 600V |
Resolution | 0.1V |
Accuracy | 50Hz to 400Hz ± (% of Rdg + Digits) ± (2% + 3) |
Input Impedance | 3MΩ (nominal) < 100pF |
Common Mode Rejection Ratio (1kΩ unbalanced) | >60dB at DC, 50 or 60Hz |
Overload Protection | 600V rms or DC |
Earth Bond Resistance Measurements | |
Range/Resolution | 20Ω: 0.01Ω 200Ω: 0.1Ω 2000Ω: 1.0Ω 20kΩ: 0.01kΩ |
Accuracy | ± (1.5% + 3) |
Overload Protection | 2V rms or DC |
Open Circuit Test Voltage | >4V, <8V |
Short Circuit Current | >200mA |
Insulation Specifications | |
Measurement Range | 1507: 0.01MΩ to 10GΩ |
Test Voltage | 50V, 100V, 250V, 500V, 1000V |
Test Voltage Accuracy | + 20%, -0% |
Short Circuit Current | 1mA nominal |
Auto Discharge | Discharge time < 0.5 seconds for C = 1μF or less |
Live Circuit Indicator | Inhibit test if terminal voltage >30V prior to initialisation of test |
Maximum Capacitive Load | Operable with up to 1μF load |
Measurement Accuracy | 50V: ±(3% + 5) 100V: ±(3% + 5) 250V: ±(1.5% + 5) 500V: ±(1.5% + 5) 1000V: ±(1.5% + 5) to 2000MΩ, ±(10% + 3) above 2000MΩ |
General Specifications | |
Maximum Voltage Applied to Any Terminal | 600V AC rms or DC |
Storage Temperature | -40 to 60°C (-40 to 140°F) |
Operating Temperature | -20 to 55°C (-4 to 131°F) |
Temperature Coefficient | 0.05x (specified accuracy) per °C for temperatures < 18°C or > 28°C (<64°F or >82°F) |
Relative Humidity | 0 to 95% @ 10°C to 30°C (50°F to 86°F) 0 to 75% @ 30°C to 40°C (86°F to 104°F) 0 to 40% @ 40°C to 55°C (104°F to 131°F) |
Vibration | Random, 2g, 5-500Hz per MIL-PRF-28800F, class 2 instrument |
Shock | 1m drop per IEC 61010-1 2nd Edition (1m drop test, six sides, oak floor) |
Electromagnetic Compatibility | In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1: 1997) |
Safety | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600V (CAT IV) |
Certifications | CSA per standard CSA/CAN C22.2 No 61010-1-04; TUV per standard IEC/EN 61010-1 2nd Edition |
Batteries | Four x AA batteries (NEDA 15A or IEC LR6) |
Battery Life | Insulation test use: Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000V into 1MΩ with a duty cycle of 5 seconds on and 25 seconds off. Resistance measurements: Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1Ω with a duty cycle of 5 seconds on and 25 seconds off |
Size | 5.0cm H x 10.0cm W x 20.3cm L (1.97" x 3.94" x 8.00") |
Weight | 550g (1.2lb) |
IP Rating | IP40 |
Altitude | Operating: 2000m CAT IV 600V, 3000m CAT III 600V Non-Operating (Storage): 12000m |
Overrange Capability | 110% of range |