Everything you need for carrying out electrical and temperature measurements packed into one handy bundle. The first tester that's included in this package is the Fluke 116, a uniquely designed digital multimeter that's made for use by HVAC technicians. The device is ideal for use in multiple applications in heating, ventilation and air conditioning systems and allows users to carry out conventional DMM functions as well as specialist testing such as temperature and microamp testing.
The 116 is handheld, portable and easy to use with just one hand. It also comes with an integrated temperature probe, making carrying out temperature measurements quick and easy. It also includes AutoV/LoZ functions which prevent false readings because of ghost voltages and has a large white LED backlit screen for using the tester even in extremely darkened conditions.
The second device included in this package is a Fluke 62 MAX + Infrared Thermometer. This device allows users to carry out easy evaluation of absolutely any surface's temperature between a range of -30 to 650°C without the need to make physical contact with the surface via a probe.
Fluke's 62 MAX + is a pistol-shaped, ergonomically designed testing device that includes dual lasers that can be used to pinpoint exactly where the measurement should take place. Results are relayed automatically through the device's LCD screen.
Fluke 116 HVAC Multimeter
Fluke 62 MAX + Infrared Thermometer
Spend £150+ (Ex VAT) on any qualified Fluke or Beha-Amprobe product(s) and claim a free tool of your choice from the list at Fluke Promotion. Valid February 17 2025 - July 31 2025.
Claims are made direct to Fluke. Terms and conditions apply.
Maximum voltage between any terminal and earth ground |
|
||
Surge protection |
|
||
Display |
|
||
Bar graph |
|
||
Operating Temperature |
|
||
Storage Temperature |
|
||
Battery type |
|
||
Battery Life |
|
Accuracy Specifications | |||||||||||||||||
DC millivolts |
|
||||||||||||||||
DC volts |
|
||||||||||||||||
Auto volts |
|
||||||||||||||||
AC millivolts1 true-rms |
|
||||||||||||||||
AC volts1 true-rms |
|
||||||||||||||||
Continuity |
|
||||||||||||||||
Ohms |
|
||||||||||||||||
Diode Test |
|
||||||||||||||||
Capacitance |
|
||||||||||||||||
LoZ capacitance |
|
||||||||||||||||
Temperature2 (Type-K thermocouple) |
|
||||||||||||||||
AC μamps true-rms (45 Hz to 500 Hz) |
|
||||||||||||||||
DC μamps |
|
||||||||||||||||
Hz (V or A input)2 |
|
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
Mechanical & General Specifications | |||
Size |
|
||
Weight |
|
||
Warranty |
|
Temperature Range | -30 to 650°C (-22 to 1202°F) |
Accuracy |
±1°C or ±1% of reading, whichever is greater -10 to 0°C: ±2.0 -30 to -10°C: ±3.0 |
Response Time (95%) | <300ms (95% of reading) |
Spectral Response | 8 to 14 microns |
Emissivity | 0.10 to 1.00 |
Optical Resolution | 12: 1 (calculated at 90% energy) |
Display Resolution | 0.1°C (0.2°F) |
Repeatability of Readings | ±0.5% of reading or <±0.5°C (1°F), whichever is greater |
Power | AA Battery |
Battery Life | 8 Hours with Laser and Backlight On |
Weight | 255g (8.99oz) |
Size | 175 x 85 x 75mm (6.88 x 3.34 x 2.95 inches) |
Operating Temperature | 0 to 50°C (32°F to 122°F) |
Storage Temperature | -20 to 60°C (-4 to 140°F) without battery |
Operating Humidity | 10% to 90% RH non-condensing at 30°C (86°F) |
Operating Altitude | 2000m Above Mean Sea Level |
Storage Altitude | 12000m Above Mean Sea Level |
IP Rating | IP54 per IEC 60529 |
Drop Test | 3m |
Vibration and Shock | IEC 68-2-6 2.5g, 10 to 200Hz, IEC 68-2-27, 50g, 11ms |
EMC | EN 61326-1: 2006, EN 61326-2: 2006 |
Compliance | EN/ IEC 61010-1: 2001 |
Laser Safety | FDA and EN 60825-1 Class II |