An upgraded version of Fluke's 114 multimeter, the 115 includes the ability to measure resistance, continuity, frequency, capacitance and diode.
Fluke's 110 range of multimeters have been designed with electricians in mind, giving easy access to all needed functions via a rotary dial on the front of the tester. The 115 is small enough to hold in one hand, giving the user the flexibility to hold test leads in the other.
This tester can measure DC and AC voltage up to 600V, continuity to 600Ω, resistance up to 40MΩ, amps to 10A and frequency up to 50kHz. Testing results can be carried out with true-RMS enabled to accurately measure on irregular signals. A built-in LoZ mode on the 115 also ensures that accuracy is maintained and filters out the effects of ghost voltages. MIN/MAX/AVG calculations are also possible using this meter, allowing signal fluctuations to be tracked and recorded.
This digital multimeter is just one of four models available in the Fluke 110 series. The following table outlines the difference between each model in the series.
Model Number | 114 | 115 | 116 | 117 |
True RMS | √ | √ | √ | √ |
Display Counts | 6000 | 6000 | 6000 | 6000 |
Backlight | √ | √ | √ | √ |
Analogue Bargraph | √ | √ | √ | √ |
AutoVolt (Automatic AC/DC Voltage Selection) | √ | - | √ | √ |
VoltAlert (Non-Contact Voltage Detector) | - | - | - | √ |
Built-In Thermometer | - | - | √ | - |
LoZ (Low Input Impedance) | √ | - | √ | √ |
MIN/MAX/AVG Modes | √ | √ | √ | √ |
Resistance/Continuity Tests | √ | √ | √ | √ |
Frequency, Capactiance and Diode Tests | - | √ | √ | √ |
Microamps Mode | - | - | √ | - |
Display Hold | √ | √ | √ | √ |
Auto/Manual Ranging | √ | √ | √ | √ |
Low Battery Indication | √ | √ | √ | √ |
Compact Case + Removable Holster | √ | √ | √ | √ |
Spend £150+ (Ex VAT) on any qualified Fluke or Beha-Amprobe product(s) and claim a free tool of your choice from the list at Fluke Promotion. Valid February 17 2025 - July 31 2025.
Claims are made direct to Fluke. Terms and conditions apply.
Specifications | ||
Maximum Voltage Between any Terminal and Earth Ground | 600 V | |
Surge Protection | 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 | |
Display | Digital:6,000 counts, updates 4 per second | |
Bar Graph | 33 segments, updates 32 per second | |
Operating Temperature | -10 °C to + 50 °C | |
Storage Temperature | -40 °C to + 60 °C | |
Battery Type | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 | |
Battery Life | 400 hours typical, without backlight | |
Accuracy Specifications | ||
DC millivolts | Range: | 600.0 mV |
Resolution: | 0.1 mV | |
Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 | |
DC volts | Range/Resolution: | 6.000 V / 0.001 V |
Range/Resolution: | 60.00 V / 0.01 V | |
Range/Resolution: | 600.00 V / 0.1 V | |
Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 | |
AC millivolts 1 true-rms | Range: | 600.0 mV |
Resolution: | 0.1 mV | |
Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) | |
AC volts 1 true-rms | Range/Resolution: | 6.000 V / 0.001 V |
Range/Resolution: | 60.00 V / 0.01 V | |
Range/Resolution: | 600.0 V / 0.1 V | |
Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) | |
Continuity | Range: | 600 Ω |
Resolution: | 1 Ω | |
Accuracy: | Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. | |
Ohms | Range/Resolution: | 600.0 Ω / 0.1 Ω |
Range/Resolution: | 6.000 kΩ / 0.001 kΩ | |
Range/Resolution: | 60.00 kΩ / 0.01 kΩ | |
Range/Resolution: | 600.0 kΩ / 0.1 kΩ | |
Range/Resolution: | 6.000 MΩ / 0.001 MΩ | |
Accuracy: | 0.9 % + 1 | |
Range/Resolution: | 40.00 MΩ / 0.01 MΩ | |
Accuracy: | 5 % + 2 | |
Diode Test | Range/Resolution: | 2.00 V / 0.001 V |
Accuracy: | 0.9% + 2 | |
Capacitance | Range/Resolution: | 1000 nF / 1 nF |
Range/Resolution: | 10.00 µF / 0.01 µF | |
Range/Resolution: | 100.0 µF / 0.1 µF | |
Range/Resolution: | 9999 µF / 1 µF | |
Range/Resolution: | 100 µF to 1000 µF | |
Accuracy: | 1.9% + 2 | |
Range/Resolution: | > 1000 µF | |
Accuracy: | 5% + 20% | |
Lo-Z Capacitance | Range: | 1 nF to 500 µF |
Accuracy: | 10% + 2 typical | |
AC amps true-rms (45 Hz to 500Hz) | Range/Resolution: | 6.000 A / 0.001 A |
Range/Resolution: | 10.00 A / 0.01 A | |
Accuracy: | 1.5% + 3 | |
20 A overload for 30-seconds max | ||
DC amps | Range/Resolution: | 6.000 A / 0.001 A |
Range/Resolution: | 10.00 A / 0.01 A | |
Accuracy: | 1.0% + 3 | |
20 A overload for 30-seconds max | ||
Hz (V or A input) 2 | Range/Resolution: | 99.99 Hz / 0.01 Hz |
Range/Resolution: | 999.9 Hz / 0.01 Hz | |
Range/Resolution: | 9.999 kHz / 0.001 kHz | |
Range/Resolution: | 50 kHz / 0.01 kHz | |
Accuracy: | 0.1% + 2 | |
Mechanical & General Specifications | ||
Size | 167 x 84 x 46 mm (6.57" x 3.31" x 1.82") | |
Weight | 550 g | |
Warranty | 3 years |
Notes:
1) All AC voltage ranges, except Auto-V/LoZ, are specified from 1 % to 100 % of the range. Auto-V/LoZ is selected from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) The Frequency is AC-coupled, 5 Hz to 50 kHz for AC voltage, and DC-coupled, 45 Hz to 5 kHz for AC current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage