The FLIR Smart Sensor Configuration MUST be used with either a FLIR A50 or A70 Thermal Camera Core. This configuration is ideal for those requiring a thermal camera with built-in analytics and alarms. The Smart Sensor Configuration is ideal for condition monitoring and early fire detection applications.
Features of the FLIR Smart Sensor Configuration include easy HMI and SCADA integration using common industrial protocols and alarm I/O, as well as OPTIONAL simultaneous VMS video and alarm integration via ONVIF S.
FLIR A50 and A70 Thermal Camera Cores with FLIR Smart Sensor Configuration can be used as a system component for cloud and Internet of Things (IIoT) solutions to help companies protect assets, improve safety, maximise uptime, and minimise maintenance costs.
Please note that the Smart Sensor Configuration is a programming option. It is incorporated into the camera core at the point of manufacture. Therefore it MUST be purchased with a FLIR A50 / FLIR A70 Thermal Camera Core (sold separately).
Image & Optical Data | Standard Configuration | Advanced Configuration |
IR resolution | 464 × 348 (A50), 640 × 480 (A70) | |
Visual Resolution | 1280 × 960 pixels (optional) | |
Thermal Resolution | A70: 29°: <45 mK, 51°: <45 mK, 95°: <60 mK | |
A50: 29°: <35 mK, 51°: <35 mK, 95°: <45 mK | ||
Focus | Fixed, adjustable with included focus tool | |
Spatial Resolution (IFOV) |
A50: 29°: 1.2 mrad/pixel, 51°: 2.1 mrad/pixel, 95°: 4.0 mrad/pixel | |
A70: 29°: 0.84 mrad/pixel, 51°: 1.5 mrad/pixel, 95°: 2.9 mrad/pixel | ||
FOV Options | 29°, 51°, 95° | |
Detector Pitch | A50: 17 µm, A70: 12 µm | |
Spectral Range | 7.5–14.0 µm | |
Frame Rate | 30 Hz | |
Measurement | ||
Object temperature range |
-20°C to 175°C (-4°F to 347°F) 175°C to 1000°C (347°F to 1832°F) |
20°C to 175°C (-4°F to 347°F) -20°C to 250°C (-4°F to 482°F) 175°C to 1000°C (347°F to 1832°F) |
Accuracy | ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C to 35°C (59°F to 95°F) and object temperature above 0°C (32°F) | |
Measurement Analysis | ||
Standard Functions | 10 Spotmeters, 10 Boxes, 3 Deltas (difference any value/ reference/external lock), 1 Isotherm (above/below/interval), 1 Iso-coverage, 1 Reference temperature |
10 Spotmeters, 10 Boxes or Polygons, 3 Deltas (difference any value/reference/external lock), 2 Isotherm (above/below/ interval), 2 Iso-coverage, 2 Lines, 1 Polyline, 1 Reference temperature |
Automatic Hot/Cold Detection |
Standard Configuration | |
Measurement Frequency | Up to 10 Hz | |
Measurement Result Read-out |
Ethernet/IP (poll), Modbus TCP server (pull), MQTT (push), REST API (read/write), Measurements and Still image (radiometric JPEG, visual 640 × 480, visual 1280 × 960), Web interface |
Ethernet/IP (poll), Modbus TCP server/client (poll/push), MQTT (push), REST API (read/write), Measurements and Still image (radiometric JPEG, visual 640 × 480, visual 1280 × 960), Web interface |
Alarm | ||
Alarm Function | On any selected measurement function, digital in, and internal camera temperature |
|
Alarm Output | Digital out, e-mail (SMTP) (push), Ethernet/IP (pull), file transfer (FTP) (push), Modbus TCP server (poll), MQTT (push), RESTful API (pull), and store image or video |
Digital out, e-mail (SMTP) (push), Ethernet/IP (pull), file transfer (FTP) (push), Modbus TCP server/ client (poll/push), MQTT (push), RESTful API (pull), and store image or video |
Wi-Fi | ||
Connector Type | RP-SMA, female connector | |
Video Streaming, RTSP Protocol | ||
Unicast | Yes | |
Multicast | Yes | |
Radiometric RTSP | No | Compressed JPEG-LS (FLIR Radiometric) |
Multiple Image Streams | Yes, visual camera option needed (P/N T300295) | |
Video Stream 0 | ||
Streaming Resolution | 640 × 480 pixels | |
Source | Visual / IR / MSX® / FSX® (visual camera is optional) | |
Contrast Enhancement | FSX® / Histogram equalization (IR only) | |
Overlay | With/Without | |
Encoding | H.264, MPEG4, or MJPEG | |
Video Stream 1 | ||
Streaming Resolution | 1280 × 960 pixels | |
Source | Visual (visual camera is optional) | |
Overlay | No | |
Encoding | H.264, MPEG4, or MJPEG | |
Ethernet | ||
Interface | Wired, Wi-Fi (optional) | |
Connector Types | M12 8-pin X-coded, female; RP-SMA, female | |
Ethernet Type & Standard | 1000 Mbps, IEEE 802.3 | |
Ethernet Power | Power over Ethernet, PoE IEEE 802.3af class 3 | |
Ethernet Protocols | Ethernet/IP, IEEE 1588, Modbus TCP, MQTT, SNMP, TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, and MDNS (Bonjour), uPnP |
|
Digital Input/Output | ||
Connector Type | M12 Male 12-pin A-coded (shared with external power) | |
Digital Input | 2× opto-isolated, Vin (low) = 0 to 1.5 V, Vin (high) = 3 to 25 V | |
Digital Output | 3× opto-isolated, 0 to 48 V DC, max. 350 mA (derated to 200 mA at 60°C). Solid-state opto relay, 1× dedicated as fault output (NC) |
|
Power | ||
Power Consumption | 7.5 W at 24 V DC typical, 7.8 W at 48 V DC typical, 8.1 W at 48 V PoE typical |
|
External Power Operation | 24/48 V DC 8 W max | |
External Voltage | Allowed range 18 V to 56 V DC | |
Power Connection | M12 12-pin A-coded, male (shared with Digital I/O) |