FLIR Si2-LD Industrial Acoustic Imager – Leak Detection
Specifically optimised for advanced compressed air/gas leak detection, the FLIR Si2-LD Industrial Acoustic Imager can locate leaks from up to 200m (656 ft) from the source. Perfect for condition monitoring applications within the automotive, food and beverage, and pharmaceutical sectors, as well as other manufacturing-based industries, the FLIR Si2-LD Industrial Acoustic Imager delivers unparalleled performance, enhances decision support, simplifies fleet management, and integrates seamlessly with enterprise data. The FLIR Si2-LD Industrial Acoustic Imager sets a new standard in its class; maintenance managers, reliability specialists and NDT technicians can rely on this imager to find potentially expensive leaks and bearing issues before significant costs are incurred.
New Features
Building on the extensive capabilities of the FLIR Si124-LD Industrial Acoustic Imager, FLIR’s Si2-LD Industrial Acoustic Imager includes the following new features:
- 12MP digital camera
- 8x digital zoom
- 1280 x 720px, 5-inch colour screen
- Mechanical Fault mode
- Built-in LED lights
- Fleet Management functionality
- Detect leaks up to 5x smaller from 4x the distance
Advanced Leak Detection
124 microphones strategically arranged for optimum performance coupled with a 12MP digital camera ensure the FLIR Si2-LD Industrial Acoustic Imager can detect hard-to-find leaks easily and efficiently. Capable of locating leaks from up to 200m (656 ft) from the source, staff can not only pinpoint difficult-to-reach leaks but may remain a safe distance from potentially dangerous equipment.
Furthermore, an 8x digital zoom also adds to the FLIR Si2-LD Industrial Acoustic Imager’s ease of use and detection capabilities while an ergonomic, single-hand design with automatic tuning contributes to its simplicity of operation. Additionally, an integrated measurement and cost analysis function makes identifying and prioritising the repair of the most detrimental leaks obvious and quick. This feature supports the calculation of the most common industrial gases including ammonia, hydrogen, carbon dioxide, methane, helium, and argon.
Bearing Fault Analysis
In addition to locating leaks, the FLIR Si2-LD Industrial Acoustic Imager is ideal for identifying bearing faults allowing you to detect defects before equipment failure. To this end, the FLIR Si2-LD Industrial Acoustic Imager includes a Mechanical Fault mode which automatically selects and optimises filters to facilitate mechanical issue identification. This presents the opportunity to address faults earlier reducing repair costs and downtime.
Fleet Management Functionality
Suitable for large-scale industrial operations, the FLIR Si2-LD Industrial Acoustic Imager features built-in data integration and GPS enabling seamless integration into GIS platforms.
The FLIR Si2-LD Industrial Acoustic Imager is a simple-to-use sonic imager specifically designed for leak detection and mechanical fault identification.
Videos
Key Features
- Sonic imager specifically optimised for advanced compressed air/gas leak detection
- Perfect for condition monitoring
- Unparalleled performance
- Enhances decision support
- Simplifies fleet management
- Integrates seamlessly with enterprise data
- Ideal for use in manufacturing industries such as automotive, food and beverage, and pharmaceutical sectors
- Intended for maintenance managers, reliability specialists, and NDT technicians
- NEW 12MP digital camera
- NEW 8x digital zoom
- NEW 1280 x 720px, 5-inch colour screen
- NEW Mechanical Fault mode
- NEW Built-in LED lights
- NEW Fleet Management functionality
- NEW: Detect leaks up to 5x smaller from 4x the distance
- 124 microphones strategically arranged for optimum performance
- Locate leaks up to 200m (656 ft) from the source
- Ergonomic, single-handed design
- Automatic tuning
- Measurement and cost analysis function for industrial gases: ammonia, hydrogen, carbon dioxide, methane, helium, and argon
- Bearing fault analysis
- Mechanical fault identification: automatically selects and optimises filters for bearing and mechanical fault identification
- Built-in data integration
- Integrated GPS
- Seamless integration into GIS platforms
- Simple-to-use sonic imager specifically designed for leak detection and mechanical fault identification
What’s Included?
- FLIR Si2-LD Industrial Acoustic Imager – Leak Detection
- Battery
- Battery Charger
- Power Cable
- Neck Strap
- Licence Card: FLIR Si-Series Plugin for FLIR Thermal Studio, Perpetual Licence
- USB Stick
- Printed Documentation
- Hard Transport Case
FLIR Si-Series Acoustic Imaging Camera Comparison Chart
Si124-LD PLUS | Si2-LD | Si2-PD | Si2-Pro | |
Leak Detection (LD) | ✓ | ✓ | × | ✓ |
Mechanical Fault Detection (MD) | × | ✓ | × | ✓ |
Partial Discharge mode (PD) | × | × | ✓ | ✓ |
PD Severity Assessment on camera | × | × | ✓ | ✓ |
Quick start with a press of the power button | ✓ | ✓ | ✓ | ✓ |
Minimum Detectable Leak Rate (MDLR) | 0.011 l/min @ 3 m | 0.0032 l/min @ 2.5 meters | N/A | 0.0032 l/min @ 2.5 meters |
AutoFilter | ✓ | ✓ | ✓ | |
AutoDistance | ✓ | ✓ | × | ✓ |
Continuous Auto-Correct | ✓ | ✓ (improved) | ✓ (improved) | ✓ (improved) |
ATEX Certified | × | × | × | × |
Compatible with Thermal Studio | ✓ | ✓ | ✓ | ✓ |
Compatible with Acoustic Viewer | ✓ | ✓ | ✓ | ✓ |
Frequency Range 2-130kHz | × | ✓ | ✓ | ✓ |
Frequency Range 2-65kHz | ✓ | × | × | × |
Video Recording (up to 5 min) | ✓ | ✓ | ✓ | ✓ |
IP Rating | IP51 | IP54 | IP54 | IP54 |
Battery Life | Up to 2,5h (depends on ambient conditions) | Up to 2,5h (depends on ambient conditions) | ||
Detection Range | 100m in optimal conditions (optimal work range is 1-15m) | Depending on the environment and application, the range can be up to 200 meters. |
- FLIR Thermal Studio Pro Software – 12-Month Licence - T300243, typically £419.00
FLIR Si2-LD Industrial Acoustic Imager – Leak Detection Technical Specifications
Acoustic Measurement | |
Detection threshold | 20 kHz: -7 dB SPL 35 kHz: 4 dB SPL 50 kHz: 10 dB SPL 80 kHz: 36 dB SPL 100 kHz: 51 dB SPL |
Bandwidth | 2 kHz to 130 kHz |
Directional resolution | From 1° up to 0.125° |
Operating distance | From 0.3 m (1.0 ft) up to 200 m (656 ft) |
Leak localization and detection | Automatic leak recognition including estimated leak size and annual cost |
Leak rate detection threshold | 0.0032 l/min from 2.5 m, 0.0044 l/min from 6 m |
Supported gases | Compressed air, hydrogen, CO2, methane, natural gas, helium, argon, ammonia |
Other acoustic analysis modes | Mechanical fault detection |
Imaging & Optical | |
Digital camera | 12 MP color |
Camera field of view | 75° diagonal |
Video frame rate | Camera: 60 fps / Acoustic image: 30 fps / Screen: 70 fps |
Zoom | 8x Digital zoom |
Video image resolution | 1280 × 720 |
User Interface | |
Display | Size: 5 in. 1280 × 720 Resistive touch screen, TFT LCD, MIPI DSI |
Integrated flashlight | LEDs, three modes off, normal and bright |
Analysis and Reporting | |
Online | FLIR Acoustic Camera Viewer (cloud service) www.acousticviewer.flir.com |
Offline | FLIR Thermal Studio (desktop software) |
Communication & Data Storage | |
Data transfer | Wi-Fi 2.4 GHz and 5 GHz IEEE 802.11.b/g/n/ac wireless LAN USB memory stick |
Camera software update | Automatic Over The Air (OTA) wireless update or via USB connection |
Still image format | .nlz and .jpg |
Video recording & format | Up to 5 minutes (.nlz format) |
Storage, internal | 128 GB (SD card) |
Storage, external | USB 8 GB, Cloud storage capacity is unlimited |
Image annotations | Image tags and comments |
Power Supply | |
Camera power input | Nominal input voltage: 12 V DC Max input: 17 V DC , 3.3 A (limited) |
Battery | Li-Ion rechargeable battery pack (RRC 2054):14.4 V DC, 3.45 Ah, 49.68 Wh Usage: Up to 2.5 h (depends on ambient conditions & usage, needs to be retested and confirmed with final product) Charge time: approx. 2 h Max output: 16.8 V DC, 5 A |
Battery charger | Input: 19-26 V DC, 2.8 A Max output: 17.4 V DC, 4.8 A |
Environmental Data | |
Operating temperature range | -10°C to 50°C (14°F to 122°F) |
Storage temperature range | -20°C to 50°C max -20°C to 25°C recommended (determined by the battery) |
Relative humidity | 0-90% recommended |
EMC | CFR47 FCC Part 15 Subpart B |
Radio | CFR47 FCC Part 15 Subpart C/E, ETSI EN 301 489-1/-17/-19, ETSI EN 300 328, ETSI EN 301 893 |
Protection class | IP54 |
Safety | IEC 62368-1 |
Declaration of conformity | See: https://support.flir.com/resources/DoC |
Physical Data | |
Camera size | 288 mm × 182 mm × 159 mm (11 in × 7 in × 6 in) |
Camera weight | ~ 1.2 kg |
Battery size | 85 mm × 77 mm (RRC2504) |
Battery weight | ~ 0.25 kg |
Total weight (camera + battery) | ~ 1.45 kg |
Reviews
SKU | T912339 |
---|---|
Manufacturer Part Code | T912339 |