The FLIR A500f and A700f Advanced Smart Sensor Thermal Cameras have built-in analytics and alarms. They help protect assets, enhance safety, reduce maintenance costs, and optimize uptime. Ideal for outdoor monitoring and early fire detection.
These cameras operate in temperature ranges from -30°C to 50°Cand include edge computing capabilities and IIoT integration. Thermal and visible video streams can be viewed independently or simultaneously, making them suitable for VMS integrations. Easy setup and compatibility with HMI/SCADA systems give automation providers a quick start for deployment.
The cameras have up to 640 × 480 thermal resolution, FSX® (Flexible Scene Enhancement) technology, remote motorized focus, and three fields of view. Communication options like ONVIF, Modbus, MQTT, and REST API protocols enable seamless integration into security and IIoT solutions.
System Overview | A500f | A700f |
---|---|---|
IR Resolution | 464 x 348 (161,472 pixels) | 640 x 480 (307,200 pixels) |
Visual Resolution | 1280 x 960 (not applicable for the 80° version) | |
Detector Pitch | 17µm | 12µm |
MSX & FSX | Yes (MSX is not available for the 80° version) | |
Available Field of Views | 14°, 24°, 42°, 80, 14°, 24°, 42°, 80°, FlexView® dual FOV (24°/14°), FlexView® dual FOV (42°/24°) lenses | |
Focal Plane Array [FPA] | Uncooled microbolometer | |
Focus | Motorized focus, manual & on-command automatic (scene contrast method) | |
Image Frequency | 30 Hz | |
Image Storage | Records up to 100 FLIR radiometric JPEG Storage as a function of: alarm, scheduling, or user interaction (camera web) |
|
Measurement | ||
Object Temperatures | -20°C to 120°C (-4°F to 248°F) 0°C to 650°C (32°F to 1202°F) 300°C to 1500°C (572°F to 2732°F) |
-20°C to 120°C (-4°F to 248°F) 0°C to 650°C (32°F to 1202°F) 300°C to 2000°C (572°F to 3632°F) |
Accuracy | ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C-35°C (59°F-95°F) and object temperature above 0°C (32°F) | |
Readout | Measurement results: Ethernet/IP, Modbus TCP server (pull), Modbus TCP client (push), MQTT (push), REST API (GET/POST), measurements and still image (radiometric JPEG, visual 640 x 480, visual 1280 x 960), web interface | |
Automatic Hot/Cold Detection | Max./min. temperature value and position shown within the box, polygon, line or polyline | |
Measurement Presets | Yes | |
Measurement Tools | 10 spot meters, 10 boxes or mask polygons, 3 Deltas (difference any value/reference/external lock), 2 isotherms (above/below/interval), 2 iso-coverage, 1 reference temperature, 2 lines, 1 polyline, Maximum 12 measurement functions at the same time | |
Web Interface | Yes | |
Multi Streaming | Yes | |
Alarm | ||
Alarm Functions | On any selected measurement function digital in internal camera temperature |
|
Alarm Output | Digital out, e-mail (SMTP) (push), Ethernet/IP, file transfer (FTP) (push), Modbus TCP server (pull), MQTT (push), query over RESTful API (pull), store image or video | |
Encoding | Video stream: H.264, MPEG4, or MJPEG Radiometric stream: Compressed JPEG-LS over RTSP |
|
Digital Input/Output | ||
Digital I/O Connector Type | The terminal block inside the housing | |
Digital I/O Isolation Voltage | 500 VRMS | |
Digital Input Purpose | NUC, NUC disable, alarm | |
Digital Inputs | 2x optoisolated, Vin(low)= 0-1.5 V, Vin(high)= 3-25 V | |
Digital Output Purpose | As a function of alarm, output to an external device, Fault (NC) | |
Digital Outputs | 3x optoisolated, 0-48 V DC, max. 350 mA; solid-state opto relay 1x dedicated as Fault output (NC) |
|
Cable Glands | 1x M12, 1x M16, 1x M20 | |
Ethernet | ||
Ethernet | For control, result, image, and power | |
Ethernet Communication | TCP/IP socket-based FLIR proprietary | |
Ethernet Connector Type | IP67 rated RJ45 port | |
Ethernet Interface | Wired | |
Ethernet Power | Power over Ethernet, PoE IEEE 802.3af class 3 EtherNet/IP, IEEE 1588, Modbus TCP, MQTT, SNMP, TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP, PoE injector sold separately | |
Environmental Data | ||
Operating Temperature Range | -30°C to 50°C (-22°F to 122°F) | |
EMC | EN50130-4, EN61000-6-3, EN55022 Class B, FCC Part. 15 Class B | |
Encapsulation | IP67 | |
Physical Data | ||
Size [L x W x H] | 51.5 cm x 17.7 cm x 22.9 cm (20.28 in x 6.97 in x 9.02 in) | |
Housing Material | Aluminium housing, sun-shield in ABS | |
System Features | ||
Heater | 8W, electronically controlled, T_ON 20°C ±2°C (68°F ±4°F), T_OFF 23°C ±2°C (73.4°F ±4°F) | |
ONVIF Conformance | Yes. ONVIF Profile S | |
Window Transmission | Automatic, based on window temperature | |
Power Consumption | 30W PoE, PoE+, Type 2. IEEE 802.3af, IEEE 802.3at/PoE Plus |