All ETI Products

ETI 860-860 Legionella Digital Thermometer Testing Kit

SKU
860-860
Rating:
0%
(0)
Reward Points
:
155
£186.60 £155.50
In Stock
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
ETI 860-860 Legionnaires' Digital Thermometer Kit

Preventing the spread of Legionnaire's disease is an essential in any workplace; use this comprehensive digital thermometer kit to check that water temperatures are correctly regulated and Legionella bacteria spread is stopped before it becomes a serious issue.

What's Included?

  • 1 x ETI 221-041 Therma Differential Digital Thermometer
  • 1 x 123-160 Penetration Type K Temperature Probe
  • 1 x 123-030 Precision Ribbon Type K Surface Temperature Probe
  • 1 x 133-362 PTFE Wire Type K Temperature Probe
  • 1 x 806-150 Water-Resistant Countdown Timer
  • 1 x 836-022 Tub of 35 Probe Wipes
  • 1 x 834-150 ABS Carrying Case
  • Traceable Certificate of Calibration for Therma Differential Thermometer

Testing for Legionella with the ETI 860-860 Legionella Testing Kit

By law, as defined in the revised Approved Code of Practice (ACOP) issued by the Government's Health and Safety Executive (HSE), it is the responsibility of all employers, who manage premises with hot/cold water systems and/or a wet cooling systems, to prevent Legionella contamination and to prevent or control its spread.

This kit from ETI is excellent for helping to prevent the spread of this type of bacteria. Generally, Legionella bacteria start to multiply in water at temperatures between 20 to 45°C (with the spread increased by the presence of nutrients such as rust, algae, sludge and scale). To control this, water should typically be kept cold below 20°C while hot water should be stored above 60°C and distributed at 50°C.

You can use this kit to test the water in storage as well as test the surface of pipes and tanks in the water system.

The probes can be used as follows:

  • Insert the immersion probe into the water to a minimum depth of 25mm to test the overall temperature
  • Use the ribbon surface probe to take the surface temperature of pipes and tanks
  • Use the wire probe to reach spots where other probes simply won't fit

About the ETI 221-041 Therma Differential Digital Thermometer

With the ETI Therma Differential thermometer you can plug two probes in at the same time and compare temperature measurement between two different points!

When testing for Legionella, doing this will allow you to compare different parts of the water system to ensure water is being stored at the right temperature. Using the thermometer is simple - just plug in the included probes and start testing!

For added convenience the ETI Therma Differential is even fully waterproof and is rated to IP66 and IP67.

Key features of this product include:

  • Dual-input thermometer - measure temperature from two points simultaneously
  • Works with a wide variety of interchangeable type K temperature probes (sold separately)
  • Ideal for HVAC work - measure the temperature drop across radiators or the temperature rise and fall of other objects
  • Measure from each channel individually (T1 or T2) or measure the difference (T1-T2)
  • Temperature measurements from -99.9 to 299.9°C with resolution of 0.1°C and 300 to 1372°C with resolution of 1°C
  • Data hold function temporarily stores current values shown on the screen
  • MAX/MIN mode calculates the maximum and minimum temperatures taken over a period of time
  • Automatic power off helps to save battery life
  • 7500 hour battery life on 3 x 1.5V AAA batteries
  • IP66 and IP67 rated waterproof case
  • 2 year guarantee from ETI

Optional Probes

The ETI Therma Differential thermometer is suitable with even more probes than are included with this kit!

This list outlines the part numbers of compatible probes from ETI (for a more exhaustive list, please download the probe guide available as a download further below):

  • 123-160: Penetration Probe (3.3mm Diameter, 130mm Length)
  • 323-160: Penetration Probe (3.3mm Diameter, 130mm Length) with Coiled Lead
  • 123-168: Penetration Probe (3.3mm Diameter, 300mm Length)
  • 323-168: Penetration Probe (3.3mm Diameter, 300mm Length) with Coiled Lead
  • 123-159: Fast Response Probe (3.3mm Diameter, 100mm Length)
  • 323-159: Fast Response Probe (3.3mm Diameter, 100mm Length) with Coiled Lead
  • 123-100: Needle Penetration Probe (1.8mm Diameter, 130mm Length)
  • 323-100: Needle Penetration Probe (1.8mm Diameter, 130mm Length) with Coiled Lead
  • 133-170: Oven Probe (3.3mm Diameter, 130mm Length)
  • 133-173: Oven Probe without Handle (3.3mm Diameter, 130mm Length)
  • 123-060: Rigid Between Pack Probe (4.5.mm Diameter, 130mm Length)
  • 323-060: Rigid Between Pack Probe (4.5mm Diameter, 130mm Length) with Coiled Lead
  • 123-204: High Temperature Probe (1.5mm Diameter, 130mm Length)
  • 332-204: High Temperature Probe (1.5mm Diameter, 130mm Length) with Coiled Lead
  • 123-212: High Temperature Probe (3mm Diameter, 130mm Length)
  • 323-212: High Temperature Probe (3mm Diameter, 130mm Length) with Coiled Lead

ETI Therma Differential Technical Specifications

Range (with resolution of 0.1°C) -99.9 to 299.9°C
Range (with resolution of 1°C) 300 to 1372°C
Resolution 0.1°C and 1°C (depends on range)
Accuracy ±0.4°C ± 0.1% of reading
Battery 3 x 1.5V AAA batteries
Battery Life 7500 hours
Sensor Type K thermocouple
Display 15mm LCD
Dimensions 32 x 72 x 141mm
Weight 220g
ETI Legionnaires Temperature Monitoring Kit - Datasheet Datasheets ETI 860-860 Legionella Testing Kit - Optional Probe Guide Manuals & Guides

Reviews

Additional Information
SKU 860-860
Manufacturer Part Code 860-860
Country of Origin United Kingdom