Free Beanie Hat. Spend £250+ (ex VAT) View
All Di-Log Products

DiLog DLPK6790 CombiVolt 2 & PU690V Proving Unit Kit

SKU
DLPK6790
Rating:
0%
(0)
Reward Points
:
118
£141.60 £118.00
Only 1 in Stock
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
DiLog DLPK6790 CombiVolt 2 & PU690V Proving Unit Kit

As seen in the Professional Electrician & Installer.

The DiLog DLPK6790 CombiVolt 2 & PU690V Proving Unit Kit is a safe isolation kit that can be used to maintain compliance with the Electricity at Works Regulations 1989.

The DiLog DLPK6790 CombiVolt 2 & PU690V Proving Unit Kit includes the following:

  • DiLog DL6790 CombiVolt 2 Voltage & Continuity Tester
  • DiLog PU690 690V AC Proving Unit
  • DiLog CCDLPK Bespoke Carrying Pouch

The supplied DiLog CCDLPK Bespoke Pouch with a carrying strap and belt loop provides an easy and convenient method of carrying the safe isolation kit on the user’s person.  

DiLog DL6790 CombiVolt 2 Voltage Tester Description

The DiLog DL6790 CombiVolt 2 Voltage & Continuity Tester is a three-in-one voltage, continuity and phase indicator that is compliant with the BS EN 61243-3: 2014 performance and safety standard.

This two-pole voltage tester features an LED scale spanning 12V to 690V AC/DC. Voltage readings are also displayed on the DiLog DL6790 CombiVolt 2 Voltage & Continuity Tester's LCD display. The DiLog DL6790 CombiVolt 2 Voltage Tester will automatically detect voltage, even when its batteries are discharged, and will also automatically switch between voltage and continuity indication. The DiLog DL6790 CombiVolt 2 Voltage Tester can carry out continuity testing with an optical and acoustic indication.

In addition to this, the DiLog DL6790 CombiVolt 2 Voltage Tester can perform phase rotation tests and will provide single-pole phase indication.

The DiLog DL6790 CombiVolt 2 Voltage Tester is also fully compliant with GS38 and is CAT IV 600V safety rated. It features a rugged, ergonomic casing ensuring that it is easy to handle.

The DiLog DL6790 CombiVolt 2 Voltage Tester is a multifunctional, easy-to-use and reliable three-in-one indicator.

DiLog DL6790 CombiVolt 2 Voltage Tester Key Features

  • A three-in-one voltage, continuity and phase indicator
  • Compliant with the safety and performance standard BS EN 61243-3:2014
  • LED scale
  • LCD display
  • Voltage range: 12 to 690V AC/DC
  • Automatically detects voltage
  • Will continue to indicate voltage even when the batteries have been discharged
  • Automatically switches between voltage and continuity indication
  • Continuity testing with an optical and acoustic indication
  • Perform phase rotation tests
  • Provides single-pole phase indication
  • Fully compliant with GS38
  • CAT IV 600V safety rated
  • Rugged, ergonomic casing
  • Easy to handle
  • A multifunctional, easy-to-use and reliable three-in-one indicator

DiLog PU690 690V AC Proving Unit Description

The DiLog PU690 690V AC Proving Unit can be used to verify the functionality of the aforementioned DiLog DL6790 CombiVolt 2 Voltage Tester, prior to commencing work on a live circuit. It can be used to maintain compliance with safe isolation procedures and regulations.

The DiLog PU690 690V AC Proving Unit is particularly useful for checking two-pole voltage indicators in the field where a known source is limited or unreliable. It will provide a 690V AC output to the two input terminals; its in-built 200kΩ load limits the current to 3.5mA at 690V. An ultrabright LED indicates a high-voltage output.

The DiLog PU690 690V AC Proving Unit can also be used to prove high and low impedance instruments such as multimeters and clamps.

Finally, this compact and lightweight proving unit features a low battery indicator and is safety rated to CAT II 750V.

The DiLog PU690 690V AC Proving Unit can be used to ensure the DiLog DL6790 CombiVolt 2 Voltage Tester is operating safely prior to testing a live circuit.

DiLog PU690 690V AC Proving Unit Key Features

  • Verify the functionality of the DiLog DL6790 CombiVolt 2 Voltage Tester prior to testing a live circuit
  • Maintain compliance with safe isolation procedures and regulations
  • Check two-pole voltage indicators in the field where a known source is limited or unreliable
  • Provides a 690V AC output to the two input terminals
  • In-built 200kΩ load limits the current to 3.5mA at 690V
  • Ultrabright LED indicates a high-voltage output
  • Can also be used to prove high and low impedance instruments such as multimeters and clamps
  • Compact
  • Lightweight
  • Low battery indicator
  • Safety rated CAT II 750V
  • Ensure the DiLog DL6790 CombiVolt 2 Voltage Tester is operating safely prior to testing a live circuit

What’s Included?

  • DiLog DL6790 CombiVolt 2 Voltage & Continuity Tester
  • DiLog PU690 690V AC Proving Unit
  • DiLog CCDLPK Bespoke Carrying Pouch

DiLog DL6790 CombiVolt 2 Voltage Tester Technical Specifications 

2 Pole Voltage Indication
Voltage range 12 - 690V AC/DC
LED resolution 12, 24,50, 120, 230, 400 & 690V
Voltage detection Automatic
Frequency range 0 - 400Hz
Peak current 3.5mA
Operation time 30 Seconds
Acoustic AC/DC signal Yes
Auto power on <12V AC/DC
IP rating IP65
Single Pole Indication
Voltage range 100 - 690V AC
Frequency range 50 - 400Hz
Continuity
Measurement range 0 - 400kΩ
Phase Rotation Test
Voltage range 100 - 690V AC
Frequency 45 - 65Hz
Overvoltage protection 690V AC/DC
Other Information
Dimensions 225mm x 70mm x 28mm
Weight (net) 200g
Power supply 2 x 1.5V (RO3) AAA (supplied)
EAN 5060082542336

DiLog PU690 690V AC Proving Unit Technical Specifications 

Voltage Output 690V AC
Output current <3.5mA
Frequency 50 Hz
Load ≥200 KΩ
High Voltage LED Yes
Low Voltage LED Yes
Low battery indication ≤ 7.6V
Safety rating CAT II 750V
Operating temperature -10°C to 40°C at max
Storage temperature -10°C - 50°C
Relative humidity ≤70% non-condensing
Altitude Up to 2000m
Pollution Degree 2
Dimensions (H/W/D) 140mm x 80mm x 50mm
Weight (net) 400g
Power supply 6 x 1.5V (LR6) AA (supplied)
EAN 5060082543562
DiLog DLPK6790 CombiVolt 2 & PU690V Proving Unit Kit - Datasheet Datasheets DiLog PU690 690V AC Proving Unit - Datasheet Datasheets DiLog DL6790 CombiVolt 2 Voltage Tester - Datasheet Datasheets DiLog PU690 690V AC Proving Unit - User Manual Manuals & Guides DiLog CombiVolt Voltage Testers - User Manual Manuals & Guides

Reviews

Additional Information
SKU DLPK6790
Manufacturer Part Code DLPK6790