As seen in the Professional Electrician & Installer.
The DiLog DLPK6790 CombiVolt 2 & PU690V Proving Unit Kit is a safe isolation kit that can be used to maintain compliance with the Electricity at Works Regulations 1989.
The DiLog DLPK6790 CombiVolt 2 & PU690V Proving Unit Kit includes the following:
- DiLog DL6790 CombiVolt 2 Voltage & Continuity Tester
- DiLog PU690 690V AC Proving Unit
- DiLog CCDLPK Bespoke Carrying Pouch
The supplied DiLog CCDLPK Bespoke Pouch with a carrying strap and belt loop provides an easy and convenient method of carrying the safe isolation kit on the user’s person.
DiLog DL6790 CombiVolt 2 Voltage Tester Description
The DiLog DL6790 CombiVolt 2 Voltage & Continuity Tester is a three-in-one voltage, continuity and phase indicator that is compliant with the BS EN 61243-3: 2014 performance and safety standard.
This two-pole voltage tester features an LED scale spanning 12V to 690V AC/DC. Voltage readings are also displayed on the DiLog DL6790 CombiVolt 2 Voltage & Continuity Tester's LCD display. The DiLog DL6790 CombiVolt 2 Voltage Tester will automatically detect voltage, even when its batteries are discharged, and will also automatically switch between voltage and continuity indication. The DiLog DL6790 CombiVolt 2 Voltage Tester can carry out continuity testing with an optical and acoustic indication.
In addition to this, the DiLog DL6790 CombiVolt 2 Voltage Tester can perform phase rotation tests and will provide single-pole phase indication.
The DiLog DL6790 CombiVolt 2 Voltage Tester is also fully compliant with GS38 and is CAT IV 600V safety rated. It features a rugged, ergonomic casing ensuring that it is easy to handle.
The DiLog DL6790 CombiVolt 2 Voltage Tester is a multifunctional, easy-to-use and reliable three-in-one indicator.
DiLog DL6790 CombiVolt 2 Voltage Tester Key Features
- A three-in-one voltage, continuity and phase indicator
- Compliant with the safety and performance standard BS EN 61243-3:2014
- LED scale
- LCD display
- Voltage range: 12 to 690V AC/DC
- Automatically detects voltage
- Will continue to indicate voltage even when the batteries have been discharged
- Automatically switches between voltage and continuity indication
- Continuity testing with an optical and acoustic indication
- Perform phase rotation tests
- Provides single-pole phase indication
- Fully compliant with GS38
- CAT IV 600V safety rated
- Rugged, ergonomic casing
- Easy to handle
- A multifunctional, easy-to-use and reliable three-in-one indicator
DiLog PU690 690V AC Proving Unit Description
The DiLog PU690 690V AC Proving Unit can be used to verify the functionality of the aforementioned DiLog DL6790 CombiVolt 2 Voltage Tester, prior to commencing work on a live circuit. It can be used to maintain compliance with safe isolation procedures and regulations.
The DiLog PU690 690V AC Proving Unit is particularly useful for checking two-pole voltage indicators in the field where a known source is limited or unreliable. It will provide a 690V AC output to the two input terminals; its in-built 200kΩ load limits the current to 3.5mA at 690V. An ultrabright LED indicates a high-voltage output.
The DiLog PU690 690V AC Proving Unit can also be used to prove high and low impedance instruments such as multimeters and clamps.
Finally, this compact and lightweight proving unit features a low battery indicator and is safety rated to CAT II 750V.
The DiLog PU690 690V AC Proving Unit can be used to ensure the DiLog DL6790 CombiVolt 2 Voltage Tester is operating safely prior to testing a live circuit.
DiLog PU690 690V AC Proving Unit Key Features
- Verify the functionality of the DiLog DL6790 CombiVolt 2 Voltage Tester prior to testing a live circuit
- Maintain compliance with safe isolation procedures and regulations
- Check two-pole voltage indicators in the field where a known source is limited or unreliable
- Provides a 690V AC output to the two input terminals
- In-built 200kΩ load limits the current to 3.5mA at 690V
- Ultrabright LED indicates a high-voltage output
- Can also be used to prove high and low impedance instruments such as multimeters and clamps
- Compact
- Lightweight
- Low battery indicator
- Safety rated CAT II 750V
- Ensure the DiLog DL6790 CombiVolt 2 Voltage Tester is operating safely prior to testing a live circuit
What’s Included?
- DiLog DL6790 CombiVolt 2 Voltage & Continuity Tester
- DiLog PU690 690V AC Proving Unit
- DiLog CCDLPK Bespoke Carrying Pouch
DiLog DL6790 CombiVolt 2 Voltage Tester Technical Specifications
2 Pole Voltage Indication | |
Voltage range | 12 - 690V AC/DC |
LED resolution | 12, 24,50, 120, 230, 400 & 690V |
Voltage detection | Automatic |
Frequency range | 0 - 400Hz |
Peak current | 3.5mA |
Operation time | 30 Seconds |
Acoustic AC/DC signal | Yes |
Auto power on | <12V AC/DC |
IP rating | IP65 |
Single Pole Indication | |
Voltage range | 100 - 690V AC |
Frequency range | 50 - 400Hz |
Continuity | |
Measurement range | 0 - 400kΩ |
Phase Rotation Test | |
Voltage range | 100 - 690V AC |
Frequency | 45 - 65Hz |
Overvoltage protection | 690V AC/DC |
Other Information | |
Dimensions | 225mm x 70mm x 28mm |
Weight (net) | 200g |
Power supply | 2 x 1.5V (RO3) AAA (supplied) |
EAN | 5060082542336 |
DiLog PU690 690V AC Proving Unit Technical Specifications
Voltage Output | 690V AC |
Output current | <3.5mA |
Frequency | 50 Hz |
Load | ≥200 KΩ |
High Voltage LED | Yes |
Low Voltage LED | Yes |
Low battery indication | ≤ 7.6V |
Safety rating | CAT II 750V |
Operating temperature | -10°C to 40°C at max |
Storage temperature | -10°C - 50°C |
Relative humidity | ≤70% non-condensing |
Altitude | Up to 2000m |
Pollution Degree | 2 |
Dimensions (H/W/D) | 140mm x 80mm x 50mm |
Weight (net) | 400g |
Power supply | 6 x 1.5V (LR6) AA (supplied) |
EAN | 5060082543562 |
Reviews
SKU | DLPK6790 |
---|---|
Manufacturer Part Code | DLPK6790 |