As seen in the Professional Electrician & Installer.
The DiLog DLPK6780 CombiVolt 1 & PU690V Proving Unit Kit can be used to maintain compliance with the Electricity at Works Regulations 1989. This safe isolation kit includes the following:
- DiLog DL6780 CombiVolt 1 Voltage & Continuity Tester
- DiLog PU690 690V AC Proving Unit
- DiLog CCDLPK Bespoke Carrying Pouch
The user can carry the DiLog DLPK6780 CombiVolt 1 & PU690V Proving Unit Kit on his/her person using the bespoke DiLog CCDLPK Pouch with a carrying strap and belt loop.
DiLog DL6780 CombiVolt 1 Voltage & Continuity Tester Description
The DiLog DL6780 CombiVolt 1 Voltage & Continuity Tester is a three-in-one voltage, continuity and phase indicator. In addition to indicating the presence of voltage and continuity, the DiLog DL6780 CombiVolt 1 Voltage & Continuity Tester can perform single-pole phase indication and phase rotation tests.
The DiLog DL6780 CombiVolt 1 Voltage & Continuity Tester will automatically detect voltage. It indicates the voltage level via its LED scale which covers 12V to 690V AC/DC. Furthermore, the DiLog DL6780 CombiVolt 1 Voltage & Continuity Tester will automatically switch between voltage and continuity detection and is capable of performing continuity tests with optical and acoustic indications.
This ergonomic and rugged two-pole voltage tester is compliant with GS38 and the safety and performance requirements of BS EN 61243-3:2014. It is also CAT IV 600V safety rated.
The DiLog DL6780 CombiVolt 1 Voltage & Continuity Tester is an easy-to-handle and easy-to-use, three-in-one voltage, continuity and phase tester.
DiLog DL6780 CombiVolt 1 Voltage & Continuity Tester Key Features
- Three-in-one voltage, continuity and phase indicator
- Single-pole phase indication
- Phase rotation tests
- Automatically detects voltage
- Indicates the voltage level via the LED scale
- Voltage range: 12V to 690V AC/DC
- Automatically switches between voltage and continuity detection
- Continuity testing with optical and acoustic indication
- Ergonomic
- Rugged
- Compliant with GS38
- Safety rated to CAT IV 600V
- Compliant with the safety and performance requirements of BS EN 61243-3:2014
- An easy-to-handle, easy-to-use, three-in-one voltage, continuity and phase tester
DiLog PU690 690V AC Proving Unit Description
The DiLog PU690 690V AC Proving Unit can be used to check that the DiLog DL6780 CombiVolt 1 Voltage & Continuity Tester is functioning correctly and safely prior to commencing work on live circuits.
This compact and lightweight proving unit is safety rated to CAT II 750V. It is especially useful for checking two-pole voltage testers in the field where a known source is limited or unreliable. The DiLog PU690 690V AC Proving Unit is also suitable for checking high and low impedance instruments such as multimeters and clamps.
The DiLog PU690 690V AC Proving Unit provides a 690V AC voltage output to the two input terminals; its in-built 200kΩ load limits the current to 3.5mA at 690V. The DiLog PU690 690V AC Proving Unit’s ultrabright LED indicates high voltage output. This proving unit also includes a low battery indicator.
The DiLog PU690 690V AC Proving Unit provides an easy and convenient method of maintaining compliance with safe isolation procedures and regulations.
DiLog PU690 690V AC Proving Unit Key Features
- Check that the DiLog DL6780 CombiVolt 1 Voltage & Continuity Tester is functioning correctly and safely prior to testing live circuits
- Safety rated to CAT II 750V
- Check two-pole voltage testers in the field where a known source is limited or unreliable
- Verify high- and low-impedance such as multimeters and clamps
- Provides a 690V AC voltage output to the two input terminals
- The built-in 200kΩ load limits the current to 3.5mA at 690V
- Ultrabright LED indicates a high voltage output
- Low battery indicator
- Provides an easy and convenient method of maintaining compliance with safe isolation procedures and regulations
What’s Included?
- DiLog DL6780 CombiVolt 1 Voltage & Continuity Tester
- DiLog PU690 690V AC Proving Unit
- DiLog CCDLPK Bespoke Carrying Pouch
DiLog DL6780 CombiVolt 1 Voltage Tester Technical Specifications
2 Pole Voltage Indication | |
Voltage range | 12 - 690V AC/DC |
LED resolution | 12, 24,50, 120, 230, 400 & 690V |
Voltage detection | Automatic |
Frequency range | 0 - 400Hz |
Peak current | 3.5mA |
Operation time | 30 Seconds |
Acoustic AC/DC signal | Yes |
Auto power on | <12V AC/DC |
IP rating | IP65 |
Single Pole Indication | |
Voltage range | 100 - 690V AC |
Frequency range | 50 - 400Hz |
Continuity | |
Measurement range | 0 - 400kΩ |
Phase Rotation Test | |
Voltage range | 100 - 690V AC |
Frequency | 45 - 65Hz |
Overvoltage protection | 690V AC/DC |
Other Information | |
Dimensions | 225mm x 70mm x 28mm |
Weight (net) | 200g |
Power supply | 2 x 1.5V (RO3) AAA (supplied) |
EAN | 5060082542336 |
DiLog PU690 690V AC Proving Unit Technical Specifications
Voltage Output | 690V AC |
Output current | <3.5mA |
Frequency | 50 Hz |
Load | ≥200 KΩ |
High Voltage LED | Yes |
Low Voltage LED | Yes |
Low battery indication | ≤ 7.6V |
Safety rating | CAT II 750V |
Operating temperature | -10°C to 40°C at max |
Storage temperature | -10°C - 50°C |
Relative humidity | ≤70% non-condensing |
Altitude | Up to 2000m |
Pollution Degree | 2 |
Dimensions (H/W/D) | 140mm x 80mm x 50mm |
Weight (net) | 400g |
Power supply | 6 x 1.5V (LR6) AA (supplied) |
EAN | 5060082543562 |
Reviews
SKU | DLPK6780 |
---|---|
Manufacturer Part Code | DLPK6780 |