The Crowcon Triple Plus+ Multigas Personal Detector Monitor with IR Sensor – Non-Pumped is available in four standard configurations, please see the table below.
Product Code | Description |
TRU-01-EA-Z | 4 gas - IR sensor detection of Methane (CH4 % LEL), gas sensor detection of Oxygen (O2), Hydrogen Sulphide (H2S), Carbon Monoxide (CO) - non-pumped |
TRU-02-EA-Z | 3 gas - IR sensor detection of Methane (CH4 % LEL), gas sensor detection of Oxygen (O2), Hydrogen Sulphide (H2S) - non-pumped |
TRU-03-EA-Z | 2 gas - IR sensor detection of Methane (CH4 % LEL), gas sensor detection of Oxygen (O2) - non-pumped |
TRU-04-EA-Z | 2 gas - Dual IR Sensor detection of Methane (CH4 % LEL & % vol)., gas sensor detection of Oxygen (O2) - non-pumped |
However, this product is completely configurable, for further information, or to place an order for a configuration not listed above, please contact our sales team before purchase. A list of available gas sensors can be found under ‘Technical Specifications’.
Further to this, the above models are set to English ATEX as standard, for different regions/alarms please contact our sales team before purchase. A table of available regions and alarm levels can be found below.
Region/ Approval | Description |
EA | English ATEX |
NU | American UL |
SA | Spanish ATEX |
GA | German ATEX |
DA | Dutch ATEX |
IA | Italian ATEX |
FA | French ATEX |
PA | Polish ATEX |
Crowcon Triple Plus+ Multigas Personal Monitor with IR Sensor – Non-Pumped Description
The Crowcon Triple Plus+ Multigas Personal Monitor with IR Sensor – Non-Pumped has a greater scope for use as a result of its IR sensor.
The IR sensor ensures that the Crowcon Triple Plus+ Multigas Personal Monitor remains functional even in areas with low or non-existent oxygen concentrations; situations in which a traditional catalytic pellistor sensor would be unable to perform effectively. IR sensors are also highly functional in areas with high-gas concentrations as they remain un-poisoned by the surrounding gases.
These sensors are available with single or dual range measurements and so are able to detect hydrocarbons in %LEL and % vol, alternatively, IR sensors which detect CO2 between 0-5% are also available. The IR sensor’s extensive measurement capabilities help to make the Crowcon Triple Plus+ Multigas Personal Monitor with IR Sensor suitable for applications such as tank and line purging.
Further to this, the IR sensor is resilient and has a long life, reducing the frequency with which the user will have to replace it, thereby lowering the cost of ownership.
Like the Crowcon Triple Plus+ Personal Gas Monitors, which do not feature an IR sensor, this model also contains unique LIBRA lithium-ion battery technology. Similarly, the Crowcon Triple Plus+ with IR Sensor also emits a visual LED light alarm (located at the top of the instrument), and an audible 85dB alarm when the instrument detects hazardous levels of gases. It too features a Time- Weighted Average warning ensuring that the user is not exposed to dangerous gas concentrations over the course of his/her shift.
Further to this, it is easy to keep track of data gathered by these units across a number of sites as these instruments are capable of logging data for one-hundred hours; data which can be annotated to include the user’s name and the name of the site. It is possible to pre-configure users’ names and site names to the unit in order to facilitate quick and easy selection.
The Crowcon Triple Plus+ Multigas Personal Monitor with IR Sensor – Non-Pumped also features a number of other functions which work to maintain both the user’s safety and the accuracy of the instrument’s detection. It features a QuickCal function for fast calibration and a simple Windows™ software interface, which allows the user to calibrate the gas monitor with or without connecting to a PC.
Additionally, this instrument’s low battery indicator and confidence blip both help to keep the user informed of the monitor’s level of functionality.
The Crowcon Triple Plus+ Multigas Personal Monitor with IR Sensor – Non-Pumped is intrinsically safe and includes a selection of flammable gas correction factors. It also features a crack and shatter resistant Triax™ casing; a unique internal design which resists harsh treatment and is fully buoyant, ensuring that it can be recovered from water easily should the need arise.
These physical features combined with the Crowcon Triple Plus+ Multigas Personal Monitor’s interchangeable gas sensor modules and IR sensor capabilities mean that this instrument can be used across a wide variety of industrial sites.
Crowcon Triple Plus+ Multigas Personal Monitor with IR Sensor – Non-Pumped Key Features
- Multigas detector with IR sensor available in four standard configurations
- Completely customisable product, for alternative sensors please contact our sales team
- Can be configured to a variety of regions and approvals
- IR sensor remains functional in places a catalytic pellistor sensor would not
- IR sensor functions in inert areas and areas with low oxygen concentrations
- IR sensor is not poisoned or affected by high concentrations of other gases
- IR Sensors have single or dual range measurement
- IR sensor can detect hydrocarbons in %LEL and/or % vol. or can detect CO2 between 0 and 5%
- IR sensor suitable for use during applications such as tank and line purging
- IR sensor has a long life
- Unique LIBRA lithium-ion battery technology
- Emits visual LED light alarm (located at the top of the instrument)
- Emits audible 85dB alarm
- Time-Weighted Average warning
- 100 hours data logging
- Annotate data to include the user’s name and site name
- Pre-configure users’ names and site names to files on the instrument
- QuickCal function for fast calibration
- Simple Windows™ software interface, which allows the user to calibrate the gas monitor with or without connecting to a PC
- Low battery indicator
- Confidence blip
- Intrinsically safe
- Selection of flammable gas correction factors
- Crack and shatter resistant Triax™ casing
- Unique internal design which resists harsh treatment
- Fully buoyant
- Interchangeable gas sensor modules
What’s Included?
- Your Choice of Crowcon Triple Plus+ Multigas Personal Monitor with IR Sensor – Non-Pumped
- User Manual
- Shoulder Strap
- Allen Keys
Optional Accessories
*** Please be aware that these instruments are NOT supplied with a charger or power supply, these products must be ordered separately. ***
To add any of the below accessories to your order, please contact our sales team before purchase.
Triple Plus+ Battery Chargers | |
C01546 | Charger (no power supply), two rate charging of complete instrument |
C01550 | Charger with 230V power pack without plug |
C01551 | Charger with 110V power pack without plug |
C011321 | Charger with multi-region power supply (includes UK, EU, US and Australian plug adaptors) |
C03580 | Multi-region power supply (includes UK, EU, US and Australian plug adaptors) |
C01440 | Charger/Interface II international without plug |
C01327 | Computer lead assembly 9 way to 9 way |
C01296 | Charging lead for vehicle lighter socket lead |
Triple Plus+ Accessories | |
C01685 | Aspirator pouch (includes aspirator, 2m hose and flow adaptor) |
C01007 | Carrying case and belt |
C01323 | Shoulder strap |
C01325 | Baffle plate to protect sensor apertures |
C01097 | 1m sample Probe |
C01757 | Telescopic aspirator Probe |
M04032 | Aspirator hose - per metre |
FIL29001 | in-line water trap/particulate filter inc. filter element |
FIL99008 | Filter element, price per element (minimum order quantity 10) for FIL29001 |
C03141 | Six metre drop line |
C01985 | Single sensor calibration adaptor |
Crowcon Triple Plus+ Multigas Personal Monitor with IR Sensor – Non-Pumped Technical Specifications
Size | 118 x 200 x 73mm (4.65 x 7.8 x 2.9ins) |
Weight | 880g gas (31oz) |
Alarms | Piercing, rapid intermittent, piezo-electric tone 85 dB at 1 m Confidence blip (selectable) Distinctive double blip for low battery with user accept Gas hazard: vivid flashing red LED Instrument is working: slow flashing green LED Low battery: distinctive double flash of green LED |
Display | 2 lines of 24 characters, dot matrix high contrast LCD with back light operating for 30 minutes Values and units for up to 4 gases displayed simultaneously at current, TWA or peak levels Low battery, pump failure, real time and elapsed time, calibration and configuration data also displayed |
Data Logging | Adjustable sample rate, 100 hours at 1 minute sample rate (maximum 6000 data points per channel), logging of events, user and site |
Battery | Rechargeable Li-ion batterypack Standard instrument >12 hours Pumped instrument >10 hours Charging: Dual rate drop-in charger; Dual rate charger/PC interface |
Expected Sensor Life | Flammable: 5 years (Triple Plus+) IR: 5 years (Triple Plus+ IR) Toxic: 3 years Oxygen: 2 years |
Typical Response Times | Methane 20s (Triple Plus+) IR 20s (Triple Plus+IR), Oxygen 10s, typical Toxic Gas 20s |
Sampling | Optional internal electric pump with on/off button |
Operating temperature | -20°C to +50°C (-4°F to 122°F) |
Humidity | 20 to 90% RH non-condensing |
Ingress Protection | IP65 |
Approvals | Europe: ATEX II 2G: Ex ib d IIC T4 Gb North America: Class I Division 1, Groups A, B, C and D |
Safety Standards | Europe: EN50014, EN50020, EN50081-2, EN50270, EN50082-2 North America: UL 913, CSA 22.2 No.157 (SFA3009 Triple Plus+) |
Calibration | Tetra can be routinely calibrated manually using the menu, using Crowcon Protables PC software or automatically using Checkbox IMH. |
Possible Gas Sensors
Product Code | Description |
CH4TRP | 0-100% LEL methane |
C3H8TRP | 0-100% LEL propane |
C5H12TRP | 0-100% LEL pentane |
C4H10TRP | 0-100% LEL butane |
C2H4TRP | 0-100% LEL ethylene |
H2TRP | 0-100% LEL hydrogen |
FLAMTRPUSA | 0-100% LEL flammable gas USA alarms UL approval (specify calibration) |
FLAMTRPAUS | 0-100% LEL flammable gas AUS alarms (specify calibration) |
CH4TRPDRLEL | 0-100% LEL methane for dual range % LEL/% vol. units |
CH4TRPDRVOL | 0-100% vol. methane for dual range % LEL/% vol. units |
H2TRPDR | 0-10% vol. Hydrogen single or for dual range (with H2TRP) |
O2TRP | 0-25% oxygen - 2 year sensor |
COTRP | 0-500ppm carbon monoxide |
COTRPUSA | 0-500ppm carbon monoxide (US alarms UL approval) |
COTRPAUS | 0-500ppm carbon monoxide (AUS alarms) |
COTRPCOMP | 0-500ppm carbon monoxide (H2 compensated)** |
H2STRP | 0-50ppm hydrogen sulphide |
H2STRPALM | 0-50ppm hydrogen sulphide (Almeer only 0-200ppm) |
H2STRPUSA | 0-50ppm hydrogen sulphide (US Alarms, UL approval) |
H2STRPAUS | 0-50ppm hydrogen sulphide (AUS alarms) |
H2STRP1000 | 0-1000ppm hydrogen sulphide |
SO2TRP | 0-10ppm sulphur dioxide (hydrogen sulphide immune) |
H2TRPPPM | 0-2000ppm hydrogen |
NOTRP | 0-100ppm nitric oxide |
NO2TRP | 0-10ppm nitrogen dioxide* |
CL2TRPUK | -5ppm chlorine* (UK alarm levels) |
CL2TRP | 0-5ppm chlorine* |
HCLTRP | 0-10ppm hydrogen chloride*/** |
HCNTRP | 0-25ppm hydrogen cyanide |
NH3TRP | 0-50ppm ammonia |
NH3TRP1000 | 0-1000ppm ammonia |
CLO2TRP | 0-1ppm chlorine dioxide* |
PH3TRPUK | 0-2ppm phosphine* (UK alarm levels) |
PH3TRP | 0-2ppm phosphine* |
ASH3TRP | 0-1ppm arsine |
VOTRP | 0-100ppm volatile organics** |
ETOTRP | 0-10ppm ethylene oxide** |
HFTRP | 0-10ppm hydrogen fluoride* |
F2TRP | 0-10ppm fluorine* |
H2TRPEC | 0-4% hydrogen electrochemical |