The Crowcon Triple Plus+ Multigas Personal Monitor - Pumped is available in four standard models, please see the table below.
Product Code | Description |
TPP-01-EA-Z | 4 gas - Methane (CH4 % LEL), Oxygen (O2), Hydrogen Sulphide (H2S), Carbon Monoxide (CO)- pumped |
TPP-02-EA-Z | 3 gas - Methane (CH4 % LEL), Oxygen (O2), Hydrogen Sulphide (H2S)- pumped |
TPP-03-EA-Z | 3 gas - Methane (CH4 % LEL), Oxygen (O2), Carbon Monoxide (CO)- pumped |
TPP-04-EA-Z | 2 gas - Methane (CH4 % LEL), Oxygen (O2)- non-pumped |
However, this instrument is completely customisable; a list of possible alternative sensors can be found under ‘Technical Specifications’. For further information, or to place an order for a configuration not listed above, please contact our sales team before purchase.
Further to this, the above models are set to English ATEX as standard, for different regions/alarms please contact our sales team before purchase. A table of available regions and alarm levels can be found below.
Region/ Approval | Description |
EA | English ATEX |
NU | American UL |
SA | Spanish ATEX |
GA | German ATEX |
DA | Dutch ATEX |
IA | Italian ATEX |
FA | French ATEX |
PA | Polish ATEX |
Crowcon Triple Plus+ Multigas Personal Monitor – Pumped Description
The Crowcon Triple Plus+ Multigas Personal Detector – Pumped can be used to perform pumped sampling and its interchangeable gas sensors extend the Crowcon Triple Plus+ Monitor’s scope for use, ensuring that this instrument can be used in a variety of locations.
Adding to this product’s practicality and versatility are its time data logging facility (one-hundred hours capacity) and ability to annotate logged data to include the user’s name and the site name. Users’ names and site names can be selected from files pre-configured to the unit.
Further to this, the Crowcon Triple Plus+ Multigas Personal Monitor has a crack and shatter resistant Triax™ casing; a unique, internal design which resists harsh treatment and is fully buoyant, these physical attributes ensure that the Crowcon Triple Plus+ can be used in harsh, challenging environments, such as industrial sites.
The Crowcon Triple Plus+ Multigas Personal Monitor –Pumped is intrinsically safe and features a range of selectable flammable gas correction factors. Its Time-Weighted Average warnings ensure that the user is not exposed to hazardous levels of gas over the course of his/her shift, whilst the 85dB alarm and vivid LED warning lights (located at the top of the instrument) ensure that the user is clearly alerted when hazardous gas levels have been detected.
This instrument helps to further protect the user by indicating low battery and emitting a confidence blip, thereby ensuring that the user is always aware of the instrument’s level of functionality.
Finally, the Crowcon Triple Plus+ Multigas Personal Monitor – Pumped makes maintaining its accuracy of detection easy, as it features a QuickCal function for fast calibration and a simple Windows™ software interface which facilitates calibration with or without a computer.
The Crowcon Triple Plus+ Multigas Personal Monitor – Pumped, with its unique LIBRA lithium-ion battery technology, is ideal for protecting workers from a variety of hazardous, industrial gases.
Crowcon Triple Plus+ Multigas Personal Monitor – Pumped Key Features
- Multigas detector available in four standard configurations
- Completely customisable product, for alternative sensors please call our sales team
- Can be configured to a variety of regions and approvals
- Can perform pumped sampling
- Interchangeable gas sensors
- Time data logging (100 hours capacity)
- Annotate logged data to include the user’s name and the site name
- Users’ names and site names can be selected from files saved in the unit
- Crack and shatter resistant Triax™ casing
- Unique internal design which resists harsh treatment
- Fully buoyant
- Intrinsically safe
- Features a range of flammable gas correction factors
- Time-Weighted Average warning
- 85dB audible alarm
- Vivid LED warning lights located at the top of the instrument
- Low battery indication
- Confidence blip
- QuickCal function for fast calibration
- Simple Windows™ software interface which facilitates calibration with or without a computer
- Unique LIBRA lithium-ion battery technology
- Ideal for protecting workers against hazardous levels of industrial gases
What’s Included?
- Your Choice of Crowcon Triple Plus+ Multigas Personal Monitor – Pumped
- User Manual
- Shoulder Strap
- Allen Keys
- Flow Plate
- 2m Hose
- Pouch
Optional Accessories
*** Please be aware that these instruments are NOT supplied with a power supply or charger, these products must be ordered separately. ***
To add any of the below accessories to your order, please contact our sales team before purchase.
Triple Plus+ Battery Chargers | |
C01546 | Charger (no power supply), two rate charging of complete instrument |
C01550 | Charger with 230V power pack without plug |
C01551 | Charger with 110V power pack without plug |
C011321 | Charger with multi-region power supply (includes UK, EU, US and Australian plug adaptors) |
C03580 | Multi-region power supply (includes UK, EU, US and Australian plug adaptors) |
C01440 | Charger/Interface II international without plug |
C01327 | Computer lead assembly 9 way to 9 way |
C01296 | Charging lead for vehicle lighter socket lead |
Triple Plus+ Accessories | |
C01685 | Aspirator pouch (includes aspirator, 2m hose and flow adaptor) |
C01007 | Carrying case and belt |
C01323 | Shoulder strap |
C01325 | Baffle plate to protect sensor apertures |
C01097 | 1m sample Probe |
C01757 | Telescopic aspirator Probe |
M04032 | Aspirator hose - per metre |
FIL29001 | in-line water trap/particulate filter inc. filter element |
FIL99008 | Filter element, price per element (minimum order quantity 10) for FIL29001 |
C03141 | Six metre drop line |
C01985 | Single sensor calibration adaptor |
Crowcon Triple Plus+ Multigas Personal Monitor – Pumped Technical Specifications
Size | 118 x 200 x 73mm (4.65 x 7.8 x 2.9ins) |
Weight | 880g gas (31oz) |
Alarms | Piercing, rapid intermittent, piezo-electric tone 85 dB at 1 m Confidence blip (selectable) Distinctive double blip for low battery with user accept Gas hazard: vivid flashing red LED Instrument is working: slow flashing green LED Low battery: distinctive double flash of green LED |
Display | 2 lines of 24 characters, dot matrix high contrast LCD with back light operating for 30 minutes Values and units for up to 4 gases displayed simultaneously at current, TWA or peak levels Low battery, pump failure, real time and elapsed time, calibration and configuration data also displayed |
Data Logging | Adjustable sample rate, 100 hours at 1 minute sample rate (maximum 6000 data points per channel), logging of events, user and site |
Battery | Rechargeable Li-ion batterypack Standard instrument >12 hours Pumped instrument >10 hours Charging: Dual rate drop-in charger; Dual rate charger/PC interface |
Expected Sensor Life | Flammable: 5 years (Triple Plus+) IR: 5 years (Triple Plus+ IR) Toxic: 3 years Oxygen: 2 years |
Typical Response Times | Methane 20s (Triple Plus+) IR 20s (Triple Plus+IR), Oxygen 10s, typical Toxic Gas 20s |
Sampling | Optional internal electric pump with on/off button |
Operating temperature | -20°C to +50°C (-4°F to 122°F) |
Humidity | 20 to 90% RH non-condensing |
Ingress Protection | IP65 |
Approvals | Europe: ATEX II 2G: Ex ib d IIC T4 Gb North America: Class I Division 1, Groups A, B, C and D |
Safety Standards | Europe: EN50014, EN50020, EN50081-2, EN50270, EN50082-2 North America: UL 913, CSA 22.2 No.157 (SFA3009 Triple Plus+) |
Calibration | Tetra can be routinely calibrated manually using the menu, using Crowcon Protables PC software or automatically using Checkbox IMH. |
Possible Gas Sensors
Product Code | Description |
CH4TRP | 0-100% LEL methane |
C3H8TRP | 0-100% LEL propane |
C5H12TRP | 0-100% LEL pentane |
C4H10TRP | 0-100% LEL butane |
C2H4TRP | 0-100% LEL ethylene |
H2TRP | 0-100% LEL hydrogen |
FLAMTRPUSA | 0-100% LEL flammable gas USA alarms UL approval (specify calibration) |
FLAMTRPAUS | 0-100% LEL flammable gas AUS alarms (specify calibration) |
CH4TRPDRLEL | 0-100% LEL methane for dual range % LEL/% vol. units |
CH4TRPDRVOL | 0-100% vol. methane for dual range % LEL/% vol. units |
H2TRPDR | 0-10% vol. Hydrogen single or for dual range (with H2TRP) |
O2TRP | 0-25% oxygen - 2 year sensor |
COTRP | 0-500ppm carbon monoxide |
COTRPUSA | 0-500ppm carbon monoxide (US alarms UL approval) |
COTRPAUS | 0-500ppm carbon monoxide (AUS alarms) |
COTRPCOMP | 0-500ppm carbon monoxide (H2 compensated)** |
H2STRP | 0-50ppm hydrogen sulphide |
H2STRPALM | 0-50ppm hydrogen sulphide (Almeer only 0-200ppm) |
H2STRPUSA | 0-50ppm hydrogen sulphide (US Alarms, UL approval) |
H2STRPAUS | 0-50ppm hydrogen sulphide (AUS alarms) |
H2STRP1000 | 0-1000ppm hydrogen sulphide |
SO2TRP | 0-10ppm sulphur dioxide (hydrogen sulphide immune) |
H2TRPPPM | 0-2000ppm hydrogen |
NOTRP | 0-100ppm nitric oxide |
NO2TRP | 0-10ppm nitrogen dioxide* |
CL2TRPUK | -5ppm chlorine* (UK alarm levels) |
CL2TRP | 0-5ppm chlorine* |
HCLTRP | 0-10ppm hydrogen chloride*/** |
HCNTRP | 0-25ppm hydrogen cyanide |
NH3TRP | 0-50ppm ammonia |
NH3TRP1000 | 0-1000ppm ammonia |
CLO2TRP | 0-1ppm chlorine dioxide* |
PH3TRPUK | 0-2ppm phosphine* (UK alarm levels) |
PH3TRP | 0-2ppm phosphine* |
ASH3TRP | 0-1ppm arsine |
VOTRP | 0-100ppm volatile organics** |
ETOTRP | 0-10ppm ethylene oxide** |
HFTRP | 0-10ppm hydrogen fluoride* |
F2TRP | 0-10ppm fluorine* |
H2TRPEC | 0-4% hydrogen electrochemical |
Reviews
SKU | Crowcon-TPP |
---|---|
Manufacturer Part Code | TPP-04-EA-Z |