The Crowcon Triple Plus+ Multigas Personal Monitor – Non-Pumped is available in four standard models, for further information please see the table below.
Product Code | Description |
TPU-01-EA-Z | 4 gas - Methane (CH4 % LEL), Oxygen (O2), Hydrogen Sulphide (H2S), Carbon Monoxide (CO)- non-pumped |
TPU-02-EA-Z | 3 gas - Methane (CH4 % LEL), Oxygen (O2), Hydrogen Sulphide (H2S)- non-pumped |
TPU-03-EA-Z | 3 gas - Methane (CH4 % LEL), Oxygen (O2), Carbon Monoxide (CO)- non-pumped |
TPU-04-EA-Z | 2 gas - Methane (CH4 % LEL), Oxygen (O2)- non-pumped |
The above models are the most common gas configurations; however this product is completely customisable, a list of available sensors can be viewed under ‘Technical Specifications’. If you require a configuration not listed above, please contact our sales team before purchase.
Further to this, the above models are set to English ATEX as standard, for different regions/alarms please contact our sales team before purchase.
Region/ Approval | Description |
EA | English ATEX |
NU | American UL |
SA | Spanish ATEX |
GA | German ATEX |
DA | Dutch ATEX |
IA | Italian ATEX |
FA | French ATEX |
PA | Polish ATEX |
Crowcon Triple Plus+ Multigas Personal Monitor – Non-Pumped Description
The Crowcon Triple Plus+ Multigas Personal Monitor – Non-Pumped is optimised for use in harsh environments and industrial conditions.
This product’s eclectic range of interchangeable sensor modules, including sensors which detect flammable gases, means that this detector can be used across a variety of sites. In addition to this the Crowcon Triple Plus+ Multigas Personal Monitor’s Triax™ casing, which doesn't crack or shatter when dropped, as well as its unique internal design which resists harsh treatment, means that this personal monitor is suitable for use in extreme environments. Its full buoyancy further extends this product’s scope for use, ensuring that this detector can be recovered from water should the needs arise.
The data detected using the Crowcon Triple Plus+ Multigas Personal Monitor – Non-Pumped can be annotated, assigning the information the name of the user and site name, both of which can be selected from pre-configured files saved in the unit. Data can be logged over the course of one-hundred hours.
Should the Crowcon Triple Plus+ Multigas Personal Monitor – Non-Pumped detect dangerous levels of the configured gases, it will alert the user via a piercing 85dB alarm and bright and colourful LED lights located at the top of the instrument. In addition to this, the Crowcon Triple Plus+ will issue a time-weighted average warning, ensuring the user is not exposed to dangerous levels of gases over the course of his/her shift.
In addition to alerting the user to dangerous gas levels, the Crowcon Triple Plus+ Multigas Personal monitor also offers piece-of-mind through its low battery indicator and confidence blip, providing the user with a greater level of certainty regarding his/her instrument’s functionality.
The Crowcon Triple Plus+ Multigas Personal Monitor – Non-Pumped puts user safety and accuracy of measurement at the forefront of its design. To this end, it features QuickCal for fast calibration and a simple Windows™ software interface with user menus which facilitate calibration with or without connecting to a computer.
Further to this, the Crowcon Triple Plus+ Multigas Personal Monitor is intrinsically safe making it suitable for use in challenging and hazardous environments and features a selection of flammable gas correction factors. Therefore the Crowcon Triple Plus+ Multigas Personal Monitor – Non-Pumped, with its unique LIBRA lithium-ion battery technology, is ideal for protecting workers from an array of hazardous, industrial gases.
Crowcon Triple Plus+ Multigas Personal Monitor – Non-Pumped Key Features
- Personal gas detector available in four standard configurations
- Completely configurable product, for alternative sensors please call our sales team
- Interchangeable gas sensors
- Triax™ casing resists shattering and cracking when dropped
- Internal design resists harsh treatment
- Fully buoyant
- Data detected can be annotated to include the user's name and site name
- Users' names and site names can be stored in files on the monitor
- Data can be logged over the course of 100 hours
- Piercing 85dB alarm issued when dangerous levels of the configured gases are detected
- Bright and colourful LED lights indicate dangerous levels of the configured gases
- Time-Weighted Average warning
- Low Battery indicator
- Confidence blip
- QuickCal for fast calibration
- Simple Windows™ software interface with user menus which facilitate calibration with or without connecting to a computer
- Intrinsically safe
- Selection of flammable gas correction factors
- Unique LIBRA lithium-ion battery technology
What’s Included?
- Your Choice of Crowcon Triple Plus+ Multigas Personal Monitor – Non-Pumped
- User Manual
- Shoulder Strap
- Allen Keys
Optional Accessories
*** Please be aware that these instruments are NOT supplied with a power supply or charger, these products must be ordered separately. ***
To add any of the below accessories to your order, please contact our sales team before purchase.
Triple Plus+ Battery Chargers | |
C01546 | Charger (no power supply), two rate charging of complete instrument |
C01550 | Charger with 230V power pack without plug |
C01551 | Charger with 110V power pack without plug |
C011321 | Charger with multi-region power supply (includes UK, EU, US and Australian plug adaptors) |
C03580 | Multi-region power supply (includes UK, EU, US and Australian plug adaptors) |
C01440 | Charger/Interface II international without plug |
C01327 | Computer lead assembly 9 way to 9 way |
C01296 | Charging lead for vehicle lighter socket lead |
Triple Plus+ Accessories | |
C01685 | Aspirator pouch (includes aspirator, 2m hose and flow adaptor) |
C01007 | Carrying case and belt |
C01323 | Shoulder strap |
C01325 | Baffle plate to protect sensor apertures |
C01097 | 1m sample Probe |
C01757 | Telescopic aspirator Probe |
M04032 | Aspirator hose - per metre |
FIL29001 | in-line water trap/particulate filter inc. filter element |
FIL99008 | Filter element, price per element (minimum order quantity 10) for FIL29001 |
C03141 | Six metre drop line |
C01985 | Single sensor calibration adaptor |
Crowcon Triple Plus+ Multigas Personal Monitor – Non-Pumped Technical Specifications
Size | 118 x 200 x 73mm (4.65 x 7.8 x 2.9ins) |
Weight | 880g gas (31oz) |
Alarms | Piercing, rapid intermittent, piezo-electric tone 85 dB at 1 m Confidence blip (selectable) Distinctive double blip for low battery with user accept Gas hazard: vivid flashing red LED Instrument is working: slow flashing green LED Low battery: distinctive double flash of green LED |
Display | 2 lines of 24 characters, dot matrix high contrast LCD with back light operating for 30 minutes Values and units for up to 4 gases displayed simultaneously at current, TWA or peak levels Low battery, pump failure, real time and elapsed time, calibration and configuration data also displayed |
Data Logging | Adjustable sample rate, 100 hours at 1 minute sample rate (maximum 6000 data points per channel), logging of events, user and site |
Battery | Rechargeable Li-ion batterypack Standard instrument >12 hours Pumped instrument >10 hours Charging: Dual rate drop-in charger; Dual rate charger/PC interface |
Expected Sensor Life | Flammable: 5 years (Triple Plus+) IR: 5 years (Triple Plus+ IR) Toxic: 3 years Oxygen: 2 years |
Typical Response Times | Methane 20s (Triple Plus+) IR 20s (Triple Plus+IR), Oxygen 10s, typical Toxic Gas 20s |
Sampling | Optional internal electric pump with on/off button |
Operating temperature | -20°C to +50°C (-4°F to 122°F) |
Humidity | 20 to 90% RH non-condensing |
Ingress Protection | IP65 |
Approvals | Europe: ATEX II 2G: Ex ib d IIC T4 Gb North America: Class I Division 1, Groups A, B, C and D |
Safety Standards | Europe: EN50014, EN50020, EN50081-2, EN50270, EN50082-2 North America: UL 913, CSA 22.2 No.157 (SFA3009 Triple Plus+) |
Calibration | Tetra can be routinely calibrated manually using the menu, using Crowcon Protables PC software or automatically using Checkbox IMH. |
Possible Gas Sensors
Product Code | Description |
CH4TRP | 0-100% LEL methane |
C3H8TRP | 0-100% LEL propane |
C5H12TRP | 0-100% LEL pentane |
C4H10TRP | 0-100% LEL butane |
C2H4TRP | 0-100% LEL ethylene |
H2TRP | 0-100% LEL hydrogen |
FLAMTRPUSA | 0-100% LEL flammable gas USA alarms UL approval (specify calibration) |
FLAMTRPAUS | 0-100% LEL flammable gas AUS alarms (specify calibration) |
CH4TRPDRLEL | 0-100% LEL methane for dual range % LEL/% vol. units |
CH4TRPDRVOL | 0-100% vol. methane for dual range % LEL/% vol. units |
H2TRPDR | 0-10% vol. Hydrogen single or for dual range (with H2TRP) |
O2TRP | 0-25% oxygen - 2 year sensor |
COTRP | 0-500ppm carbon monoxide |
COTRPUSA | 0-500ppm carbon monoxide (US alarms UL approval) |
COTRPAUS | 0-500ppm carbon monoxide (AUS alarms) |
COTRPCOMP | 0-500ppm carbon monoxide (H2 compensated)** |
H2STRP | 0-50ppm hydrogen sulphide |
H2STRPALM | 0-50ppm hydrogen sulphide (Almeer only 0-200ppm) |
H2STRPUSA | 0-50ppm hydrogen sulphide (US Alarms, UL approval) |
H2STRPAUS | 0-50ppm hydrogen sulphide (AUS alarms) |
H2STRP1000 | 0-1000ppm hydrogen sulphide |
SO2TRP | 0-10ppm sulphur dioxide (hydrogen sulphide immune) |
H2TRPPPM | 0-2000ppm hydrogen |
NOTRP | 0-100ppm nitric oxide |
NO2TRP | 0-10ppm nitrogen dioxide* |
CL2TRPUK | -5ppm chlorine* (UK alarm levels) |
CL2TRP | 0-5ppm chlorine* |
HCLTRP | 0-10ppm hydrogen chloride*/** |
HCNTRP | 0-25ppm hydrogen cyanide |
NH3TRP | 0-50ppm ammonia |
NH3TRP1000 | 0-1000ppm ammonia |
CLO2TRP | 0-1ppm chlorine dioxide* |
PH3TRPUK | 0-2ppm phosphine* (UK alarm levels) |
PH3TRP | 0-2ppm phosphine* |
ASH3TRP | 0-1ppm arsine |
VOTRP | 0-100ppm volatile organics** |
ETOTRP | 0-10ppm ethylene oxide** |
HFTRP | 0-10ppm hydrogen fluoride* |
F2TRP | 0-10ppm fluorine* |
H2TRPEC | 0-4% hydrogen electrochemical |
Reviews
SKU | Crowcon-TPU |
---|---|
Manufacturer Part Code | TPU-04-EA-Z |