Marine-approved and specifically designed for monitoring the atmosphere within tanks, the Crowcon Gas Pro TK MED Personal Gas Detector can be used as a personal gas monitor as well as to conduct tank checks and confined space pre-entry checks. There are four versions of the Crowcon Gas Pro TK MED Personal Gas Detector – 3 Gas available; please see the table below for more information.
SKU | Gases | Charging Cradle |
GTPE8AAA-ACZZRGOCZZ | CH4, O2 & CO | ✖ |
GTPE8AAA-ALZZRGOCZZ | CH4, O2 & H2S | ✖ |
GTPE8AAC-ACZZRGOCZZ | CH4, O2 & CO | ✔ |
GTPE8AAC-ALZZRGOCZZ | CH4, O2 & H2S | ✔ |
A dual IR sensor measures the concentration of methane in the atmosphere. It auto-ranges between % vol and % LEL concentrations ensuring you are always working in the correct parameter and remaining completely functional even in environments with high hydrocarbon concentrations.
In addition to this, the Crowcon Gas Pro TK MED Personal Gas Detector provides up-to-the-moment oxygen concentrations and will let you know when:
Readings are indicated on the Crowcon Gas Pro TK MED Personal Gas Detector’s top-mounted, easy-to-read display. Audible (>95dB), visual (red and blue flashing LEDs), and vibrating alarms will alert you when gas concentrations reach dangerous levels. An integrated pump and 30m-long line allow you to sample the tank quickly by gathering data from the top, middle, and base of the unit.
Compact, rugged, and lightweight (340g), the Crowcon Gas Pro TK MED Personal Gas Detector can be easily clipped to a belt or overalls.
The Crowcon Gas Pro TK MED Personal Gas Detector is a portable, versatile, and reliable three-gas monitor ideal for individuals involved in purging, freeing, and maintaining storage and transportation tanks.
Size | 43 x 130 x 84mm (1.7 x 5.1 x 3.3ins) |
Weight | 340g (11.9oz) |
Alarms | Audible 95dB Visual – all-angle dual red/blue LEDs Vibrating alert |
Display | Bright top-mounted display can be viewed while worn |
Data logging | 125hr at 10-second intervals (45,000 logs) |
Event logging | 1000 events |
Battery | Rechargeable Li-ion, 13-hour typical runtime (4 sensors, pump running) Typical charge time 7.5hr |
Sampling | Internal pump with 30m draw |
Operating temperature | -20°C to +55°C (-4°F to +131°F) |
Humidity | 10 to 95% RH non-condensing |
Ingress protection | Independently tested to IP65 and IP67 |
Approvals | IECEx: Ex db ia IIC T4 Gb Tamb -20°C to +55°C ATEX: II 2 G Ex db ia IIC T4 Gb Tamb -20°C to +55°C UL: Class 1, Division 1, Groups A, B, C, and D UL 913, UL 60079-0 and UL 60079-11 INMETRO: Ex db ia IIC T4 Gb Tamb -20°C to +55°C Marine Equipment Directive: MED 1500009 |
Compliance | FCC and CE. Complies with EMC Directive 2014/30/EU, EN50270 and EMC FFC CFR 47 Part 15, ICES-003 |
Crowcon Connect Compatible? | Yes |