All C.Scope Products

C. Scope YIRP-33-8 Signal Injector – UK Version

SKU
YIRIP-33-8
Rating:
0%
(0)
Reward Points
:
114
£137.64 £114.70
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
C. Scope YIRP-33-8 Signal Injector – UK Version

The C. Scope YIRP-33-8 Signal Injector can be used with a C. Scope Signal Generator or Transmitter to apply a signal directly to an electrical system allowing it to be traced using a C. Scope Cable Avoidance Tool or Cable Locator. The C. Scope YIRP-33-8 Signal Injector supports 8kHz and 33kHz signal outputs. 

The C. Scope YIRP-33-8 Signal Injector safely applies a signal to the electrical system via a three-pin power socket. The applied signal energises the electrical system, making the supply cable outside the building and all supply cables inside the building detectable.

For safety, the C. Scope YIRP-33-8 Signal Injector isolates the signal generator from the electrical supply.

Finally, the C. Scope YIRP-33-8 Signal Injector features a weatherproof design (IP65) and is supplied with a UK plug. A European version is available here.

The C. Scope YIRP-33-8 Signal Injector is an efficient, effective and easy-to-use tool designed to maximise cable energisation and detection.

C. Scope YIRP-33-8 Signal Injector Key Features

  • Can be used with a C. Scope Signal Generator/ Transmitter to apply signal directly to an electrical system
  • Supports 8kHz and 33kHz signal outputs
  • Safely applies a signal to the electrical system via a three-pin power socket
  • The applied signal energise the system allowing all supply cables inside and outside the building to be detected
  • Isolates the signal generator from the electrical supply for safety
  • Weatherproof design: IP65
  • Supplied with a UK plug
  • An effective, efficient, easy-to-use tool designed to maximise cable energisation and detection

What’s Included?

  • C. Scope YIRP-33-8 Signal Injector with a UK Plug

C. Scope YIRP-33-8 Signal Injector Technical Specifications 

Input Lead Length 1m (3’3.3”)
Output Lead Length 1.5m (4’11”)
Construction Encapsulated, robust housing
Moisture/dust resistant to IP54
Electrical Output (Mains side)
Electrical Isolation Class II (Double Insulated)
Mains Plug Connector UK, 3 pin to BS1363, load between Live and Earth
Maximum Voltage 250 V rms
Maximum Load <10mA (predominantly capacitive)
Frequency range 45-65Hz
Electrical Input (Signal Generator/ Transmitter side)
Connector 3 pin XLR male (industry standard)
Maximum Voltage 42 V rms
Maximum Power <250mW when driven from C.SCOPE Signal Generator/ Transmitter
Input Impedance 2000 Ohms
Frequency 32,768Hz
Safety Built to conform to BSEN61010-1:1993 and BSEN 61010-2-032:1995

Reviews

Additional Information
SKU YIRIP-33-8
Manufacturer Part Code YIRIP-33-8
Country of Origin United Kingdom