The Beha-Amprobe ULD-420 Ultrasonic Leak Detector & Transmitter can be used to find vibration, electrical discharge, and air and water leaks in pressurised and unpressurised HVAC/R, mechanical and electrical systems and equipment. To this end, this kit includes both Beha-Amprobe’s ULD-400-RE Ultrasonic Receiver and ULD-400-TE Ultrasonic Transmitter, as well as a range of accessories including headphones, earbuds, a power parabola and tubular extension. For a complete list of the products included with the Beha-Amprobe ULD-420 Ultrasonic Leak Detector & Transmitter, please see the ‘What’s Included?’ section.
For a brief introduction to Beha-Amprobe’s ULD-400 Series of Ultrasonic Detectors, please see the following video.
The Beha-Amprobe ULD-420 Ultrasonic Leak Detector & Transmitter’s wide frequency range of 20kHz to 90kHz enables it to detect a wide variety of leaks and faults. As a result, it can be used to inspect the following:
The strength of the ultrasonic signal can be viewed via the bar graph on the Beha-Amprobe ULD-400-RE Ultrasonic Receiver’s 6.35cm, LCD display and can be heard using the supplied headphones or earbuds. Listening to the converted ultrasonic signal also aids with identifying the type of fault: electrical discharge issues a ticking sound, while leaks produce a hissing noise.
The Beha-Amprobe ULD-400-RE Ultrasonic Receiver’s adjustable sensitivity allows the user to locate the source of faults more precisely, please see the following video for further information.
Moreover, the power parabola, which directs ultrasonic sound towards the sensor, and the Beha-Amprobe ULD-400-RE Ultrasonic Receiver’s filter function ensure the detector remains effective in noisy environments. The filter function removes up to three main noise frequencies; for further information, please see the following video.
Similarly, the Beha-Amprobe ULD-400-TE Ultrasonic Transmitter can be used with the Beha-Amprobe ULD-400-RE Ultrasonic Receiver to find air and water leaks in systems and equipment where there is a lack of ultrasonic sound caused by a lack of pressure. In these situations, the Beha-Amprobe ULD-400-TE Ultrasonic Transmitter can be used to create an ultrasonic signal strong enough for the Beha-Amprobe ULD-400-RE Ultrasonic Receiver to detect. This allows the user to find air and water leaks in unpressurised systems and equipment; it is particularly useful when inspecting the following:
Please see the video below for an overview of how to inspect unpressurised systems using the Beha-Amprobe ULD-400 Ultrasonic Receiver and Transmitter.
Finally, the Beha-Amprobe ULD-420 Ultrasonic Leak Detector & Transmitter also includes a detachable tubular extension for accessing difficult-to-reach areas.
The Beha-Amprobe ULD-420 Ultrasonic Leak Detector & Transmitter is a useful, versatile and effective ultrasonic diagnostic and troubleshooting tool.
** Please note that the Beha-Amprobe ULD-420 Ultrasonic Leak Detector & Transmitter CANNOT be used for combustible gas leak detection.
Spend £150+ (Ex VAT) on any qualified Fluke or Beha-Amprobe product(s) and claim a free tool of your choice from the list at Fluke Promotion. Valid February 17 2025 - July 31 2025.
Claims are made direct to Fluke. For more information and terms and conditions, visit Fluke Promotion.
Specifications | ULD-400-RE | ULD-400-TE |
Sensitivity Adjustment | Yes | N/A |
Volume Adjustment | Yes | N/A |
Signal Level Adjustment | N/A | Yes |
Earphone Jack (3.5 mm) | Yes | N/A |
Display Size | LCD 2.5 in (6.35 cm) | N/A |
Display Dimensions | 1.45 x 1.93 in (36.72 x 48.96 mm) | N/A |
Display Resolution | 240(RGB) x 320 pixels | N/A |
Display Type | TFT-LCD (262 K) | N/A |
Display Colour | True, 16bit/colour | N/A |
Frequency Range | 20 kHz to 90 kHz | Typical 40 kHz squarewave |
Filter | ±5 KHz of main noise frequency, up to three filters | N/A |
Power Supply | 4 x 1.5 V AA (LR6) alkaline batteries | 2 x 1.5 V AAA (LR03) alkaline batteries |
Power Consumption (typical) | 75 mA | 33 mA |
Battery Life (typical) | 105 hours (Alkaline) | 60 hours (Alkaline) |
Low battery indication | Yes | Yes (Red LED) |
Weight | Approx. 0.518 lb (0.235 kg) | Approx. 0.335 lb (0.152 kg) |
Dimensions | 7.547 x 2.984 x 1.791 in (183 x 75 x 43 mm) |
5.295 x 2.559 x 1.326 in (137 x 65 x 33 mm) |
APO function | 60 minutes when in idle | |
Operating Temperature | -4 °F to 122 °F (-20 °C to 50 °C) | |
Storage Temperature | -4 °F to 158 °F (-20 °C to 70 °C) | |
Operating Humidity | <80% RH | |
Pollution Degree | 2 | |
Protection | IP40 | |
Certifications | ![]() |
|
Electromagnetic Compatibility (EMC) | EN 61326-1 | |
Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) [1] [1] This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes. |