Free Beanie Hat. Spend £250+ (ex VAT) View
All BAUR Products

BAUR Frida VLF Cable Diagnostics Test Set

SKU
FRIDA
Rating:
0%
(0)
Reward Points
:
23750
£28,500.00 £23,750.00
Free UK Delivery*
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
BAUR Frida VLF Cable Diagnostics Test Set

The BAUR Frida VLF Cable Diagnostics Test Set is a very low frequency tester designed for verifying the condition of medium-voltage cables and electrical equipment (up to 20kV) such as generators, transformers and switchgear. The BAUR Frida VLF Cable Diagnostics Test Set can also be used for cable sheath testing and can measure partial discharge when used with BAUR’s PD-TaD 62 Diagnostics System (NOT included).

The BAUR Frida VLF Cable Diagnostics Test Set will test cables according to DIN VDE 0276-620/621 (CENELEC HD 620/621), IEEE 400-2012, IEEE 400.2-2013, IEC 60060-3. It is capable of performing cable sheath tests in accordance with IEC 60502/ IEC 60229 and voltage withstand tests in accordance with IEEE 433.

Very low frequency testing allows the user to locate faults in plastic- and paper-insulated, mass-impregnated cables. The BAUR Frida VLF Cable Diagnostics Test Set can locate faults quickly and without affecting the quality of the surrounding material.

The BAUR Frida VLF Cable Diagnostics Test Set features truesinus® test technology which provides a load-independent, reproducible, sinusoidal and continuous high voltage. VLF truesinus® facilitates reliable voltage tests as well as accurate dissipation factor and partial discharge measurements; it ensures that results are repeatable and comparable.

The BAUR Frida VLF Cable Diagnostics Test Set’s dissipation factor diagnostics with 0.1Hz truesinus® provides differentiated information pertaining to the ageing of paper-insulated, mass-impregnated cables and PE/XLPE cables. This allows the user to prioritise cable replacement as, when used to verify the condition of PE/XLPE cables, the dissipation factor differentiates between new, slightly or severely ‘water-tree’-damaged cables.

The BAUR Frida VLF Cable Diagnostics Test Set has a maximum test voltage of 24 kVrms/ 34 kVpeak and can provide voltage shapes including VLF truesinus®, VLF square and DC voltage. The BAUR Frida VLF Cable Diagnostics Test Set supports automatic testing and diagnostic sequences. It is quick and easy to setup.

Additionally, data can be transferred via a USB interface and managed using an Excel-based Diagnostic Reporter application.

Finally, this compact and lightweight cable fault locator features an automatic discharge unit.

The BAUR Frida VLF Cable Diagnostics Test Set is a precise, portable and powerful high-voltage testing and diagnostics instrument optimised for cable, cable sheath and electrical equipment testing.

BAUR Frida VLF Cable Diagnostics Test Set Key Features

  • Very low frequency tester for verifying the condition of medium-voltage cables and electrical equipment up to 20kV
  • Test generators, transformers and switchgear
  • Cable sheath testing
  • Measure partial discharge when used with BAUR’s PC-TaD 62 Diagnostics System (NOT included)
  • Test cables according to DIN VDE 0276-620/621 (CENELEC HD 620/621), IEEE 400-2012, IEEE 400.2-2013, and IEC 60060-3
  • Perform cable sheath tests in accordance with IEC 60502/ IEC 60229
  • Perform voltage withstand tests on electrical equipment in accordance with IEEE 433
  • Locate faults in plastic- and paper-insulated, mass-impregnated cables
  • Locate faults quickly without affecting the quality of the surrounding material
  • truesinus® provides a load-independent, reproducible, sinusoidal and continuous high voltage
  • VLF truesinus® facilitates reliable voltage tests as well as accurate dissipation factor and partial discharge measurements
  • VLF truesinus® ensures results are repeatable and comparable
  • Dissipation factor diagnostics with 0.1Hz truesinus® provides differentiated information pertaining to the ageing of cables
  • Dissipation factor indicates whether PE/XLE cables are new, slightly or severely ‘water-tree’ damaged
  • Maximum test voltage: 24 kVrms/ 34 kVpeak
  • Voltage shapes: VLF truesinus®, VLF square and DC voltage
  • Automatic testing and diagnostic sequences
  • Quick and easy to setup
  • Transfer data via a USB interface
  • Automatic discharge unit
  • Compact and lightweight
  • A precise, portable and powerful high-voltage testing and diagnostics instrument

What’s Included?

  • BAUR Frida VLF Cable Diagnostics Tester
  • HV Connection Cable, 5m (fix mounted)
  • GDR 40-136 Discharge and Earth Rod
  • Earth Cable, 5m, with Earth Terminal
  • Mains Supply Cord, 2.5m
  • Diagnostic Reporter and Video Tutorial on USB Drive
  • User Manual
  • Pocket Guide

Available Methods and Combinations of Methods

The BAUR Frida VLF Cable Diagnostics Test Set has a sister product, the BAUR Frida TD VLF Cable Diagnostics Test Set. The table below details the measurement/ test capabilities of these instruments when used independently and/or in conjunction with the BAUR PD-TaD 62 Diagnostics System. 

Method Significance and Benefits  BAUR equipment
VLF testing Easy voltage test (Verdict: Pass / Fail) frida
tan δ measurement Evaluation of the dielectric condition of the insulation, indication of PD frida TD
PD test Diagnostics of local weak points and their location frida & PD-TaD 62
Simultaneous tan δ and PD measurement Combination of statements of a tan δ measurement and PD measurement frida TD & PD-TaD 62
Shorter test duration with simultaneous tan δ and PD measurement
Better detection of hidden faults (e.g. moist joints) through conditioning of weak points and
simultaneous monitoring of tan δ values and PD activities
MWT with tan δ Evaluation of the dielectric condition of the insulation, indication of PD frida TD & PD-TaD 62
Intelligent withstand voltage test
Shorter test duration for cables in good condition
VLF cable testing with parallel PD test Localisation of faults in the cable insulation frida & PD-TaD 62
Intelligent withstand voltage test
Full MWT (VLF
cable testing with
parallel dissipation factor and
partial discharge
testing)
Evaluation of the dielectric condition of the insulation, indication of PD frida TD & PD-TaD 62
Localisation of faults in the cable insulation
Intelligent withstand voltage test with shorter test duration for cables in good condition
Shorter test duration with simultaneous tan δ and PD measurement
Better detection of hidden faults (e.g. moist joints) through conditioning of weak points and
simultaneous monitoring of tan δ values and PD activities

BAUR Frida VLF Cable Diagnostics Test Set Technical Specifications 

Output Voltage 
Frequency range 0.01 – 0.1 Hz
VLF truesinus® 1 – 24 kVrms (34 kVpeak)
VLF square wave voltage 1 – 34 kV
DC voltage ±1 – 34 kV
Resolution 0.1 kV
Accuracy 1%
Load range (VLF testing) 1 nF – 8 μF
Output Current 
Measurement range 0 – 14 mA
Resolution 1 µA
Accuracy 1%
Max. capacitive load 0.5 μF at 0.1 Hz,
24 kVrms / 34 kVpeak
1 μF at 0.05 Hz,
24 kVrms / 34 kVpeak
8 μF at 0.01 Hz,
18 kVrms / 25 kVpeak
Diagnostic Reporter Used to process and evaluate test and measurement logs, based upon MS Excel, version from MS Excel 2007
General
Input voltage 100 – 260 V, 50/60 Hz
Power consumption Max. 300 VA
Reverse voltage protected up to 13 kV
Degree of protection IP54 (in closed state)
Data interface USB 2.0
Dimensions (W x H x D) 438 x 456 x 220 mm
Weight
(incl. HV test lead)
Approx. 22 kg
Ambient temperature
(operational)
-10°C to +50°C
Storage temperature -20°C to +60°C
Safety and EMC CE-compliant in accordance with
Low Voltage Directive (2014/35/EU), EMC
Directive (2014/30/EU),
EN 60068-2-ff Environmental testing
User interface available in
13 languages
Czech, Chinese (CN), Chinese (TW), Dutch,
English, French, German, Italian, Korean,
Polish, Portuguese, Russian, Spanish
BAUR Frida & Frida TD VLF Cable Diagnostics Test Sets - Datasheet Datasheets BAUR Cable Fault Location - Application Guide Manuals & Guides

Reviews

Additional Information
SKU FRIDA