or Call 01642 931 329 to discuss alternatives
The Beha-Amprobe LH41A is specifically designed for carrying out precise measurements of low current.
An autoranging clamp meter, the LH41A measures current levels from 0-40A AC/DC with resolution of 1mA and basic accuracy of ±1.3% + 5 digits. It also includes frequency range of 40Hz to 400Hz AC.
The maximum size cable that this clamp meter can hold inside its 20mm jaws is around 19mm in diameter, making the LH41A best suited for use on smaller conductors. Once attached the LH41A will evaluate the level of detected current and display it as a value on the built-in LCD screen.
This clamp meter also includes a data hold function, auto power off facility and is CAT III 300V safety rated.
Beha-Amprobe LH41A Leakage Clamp Meter Key Features
- Precise low current measurements
- 1mA resolution
- Easy to use
- Autoranging
- Data hold
- Auto power off
- Measures current from 0-40A
- 19mm cable diameter jaws
- 4000 count display
Full List of Products Included
- Beha-Amprobe LH41A Leakage Clamp Meter
- Batteries (Installed)
- User Manual
Beha-Amprobe LH41A Technical Specifications
Operating Temperature | 0°C to + 50°C |
Storage Temperature with Battery Removed |
- 20°C to + 60°C |
Power Supply | 9 V, Alkaline battery PP3, NEDA 1604 or IEC6LR61 |
Battery Life | 15 hours dependent duty cycle |
Display | 4000 count |
Characters | 10 mm high |
Max Jaw Capacity | 19 mm ø cable |
Max Jaw Opening | 20 mm (.78 in.) |
Dimensions | 184 x 71 x 31 mm (7.2 x 2.8 x 1.2 in.) |
Weight | 235 g (1.2 Lb) |
Altitude | 2000m, indoor operation |
Measuring Range | 0 - 40 A DC or AC pk |
Autoranging | 4 A / 40A |
Resolution | 1 mA in 4 A range 10 mA in 40 A range |
Basic Accuracy | ± 1.3% + 5 digits |
Temperature Coefficient | ± 0.05% of rdg / °C |
Frequency Range | 40 Hz to 400 Hz in AC |
Overload Capacity | 150A |
Safety | CAT III, 300V |
Reviews
SKU | 3030898 |
---|---|
Manufacturer Part Code | 3030898 |
Model Ref | Amprobe LH41A |
Country of Origin | China |