The 30XR-A is a manual ranging digital multimeter that can be used to measure DC voltage, AC voltage, DC current, AC current and resistance levels. It's a great multimeter for basic testing scenarios and all electrical engineers should find a use for the 30XR.
As well as the aforementioned testing procedures the 30XR-A is also equipped with a non-contact voltage detector, allowing users to quickly and easily check that live voltages are not present on a system before hooking up the DMM. This detector can be used on voltages up to 600V AC.
The 30XR-A comes as standard with a Magne-Grip holster which allows users to attach the DMM to a wall or other surface and carry out testing procedures without actually holding the multimeter. Other additional features include a 1.5V/9V battery test under load, MAX/MIN measurements, data hold, a rotary dial for selecting testing procedures and a digital LCD display for relaying testing information.
The 30XR-A also contains four ports for the attachment of leads.
Spend £150+ (Ex VAT) on any qualified Fluke or Beha-Amprobe product(s) and claim a free tool of your choice from the list at Fluke Promotion. Valid February 17 2025 - July 31 2025.
Claims are made direct to Fluke. Terms and conditions apply.
General Specs | |
---|---|
Ranging | Manual |
Display | 3 and ½ digit LCD, 1999 counts |
Display Update Rate | 2.5/sec, nominal |
Power | 9V NEDA 1604 batteries, JIG 006P or IEC 6F22 |
Battery Life | 200 hours (typical) |
Operating Temperature | 0 to 45°C at < 70% RH |
Storage Temperature | -20 to 60°C at 80 to 80% RH with battery removed |
Dimensions | 196 x 92 x 60mm (7.7 x 3.5 x 2.4") |
Tech Specs | |
DC Voltage | |
Ranges | 200mV, 2V, 20V, 200V, 600V |
Accuracy | ±(1% rdg + 1 dgt) |
Resolution | 100μV |
Input Impedance | 10MΩ |
AC Voltage (45 to 500Hz) | |
Ranges | 200mV, 2V, 20V, 200V, 600V |
Accuracy | ±(1.5% rdg + 4 dgts) |
Resolution | 100μV |
Input Impedance | 10MΩ |
DC Current | |
Ranges | 200μA, 2mA, 20mA, 200mA, 10A |
Accuracy | 200μA to 200mA ranges: ±(1.5% rdg + 1 dgt) 10A range: ±(2.0% rdg + 3 dgts) |
Resolution | 0.1μA |
Voltage Burden (Max) | 200μA range: 1mV/μA 2mA range: 100mV/1mA 20mA range: 13mV/1mA 200mA range: 4.6mV/1mA 10A range: 40mV/1A |
AC Current (45 to 500Hz) | |
Ranges | 200μA, 2mA, 20mA, 200mA, 10A |
Accuracy | 200μA to 200mA ranges: ±(2.0% rdg + 4 dgts) 10A range: ±(2.5% rdg + 4 dgts) |
Resolution | 0.1μA |
Voltage Burden | See DC current |
Resistance | |
Ranges | 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ, 20MΩ |
Accuracy | 200Ω to 200kΩ ranges: ±(1.0% rdg + 4 dgts) 2MΩ range: ±(1.5% rdg + 4 dgts) 20MΩ range: ±(2.0% rdg + 5 dgts) |
Resolution | 100mΩ |
Open Circuit Voltage | 200Ω range: 3.0V DC All other ranges: 0.3V DC typical |
Continuity | |
Audible Indication | 75Ω |
Accuracy | ±25Ω |
Response Time | 100ms |
Diode Test | |
Test Current | 1.0mA (approx) |
Accuracy | ±(1.5% rdg + 3 dgts) |
Resolution | 0.001V |
Open Circuit Voltage | 3.0V typical |
Battery Test | |
Ranges | 1.5V, 9V |
Accuracy | ±(3.5% rdg + 2 dgts) |
Resolution | 1mV, 10mV |
Load Test Current | 1.5V range: 150mA typical 9V range: 5mA typical |
Non-Contact Voltage Detector | |
AC Voltage Range | 70 to 600V |
Indicators | Red LED light and audible tone |
Overload Protection | |
AC/DC Voltage (400mV Range) | 600V DC or 600V AC RMS 15 sec |
All Other AC/DC Voltage Ranges | 600V DC or 600V AC RMS |
AC/DC Current (μA/mA Input) | F.0 25A / 600V, Min. I.R. 100kA, (10 x 38mm) (10A for 4 minutes maximum followed by a 12 minute cooling period) |
Resistance | 600V DC or 600V rms |
Continuity | 600V DC or 600V AC RMS |
Diode Test | 600V DC or 600V AC RMS |
Battery Test | 600V DC or 600V AC RMS |