Amprobe 2100-Beta Two Pole Voltage Tester

The Beha-Amprobe 2100-Beta Two Pole Voltage Tester can be used to automatically detect and measure AC and DC voltages as well as determine voltage polarity. It can also be used to perform continuity checks.

Its LED panel indicates the voltage range, two pole phase rotation, polarity (using the results gained from single pole tests) as well as the results of continuity tests. The LCD display indicates the voltage reading.

The Beha-Amprobe 2100-Beta Two Pole Voltage Tester has a voltage measurement range of 12 to 690V AC/DC and will issue an audible alarm to indicate when a voltage of 50V AC and above, or 120V DC and above, has been detected. Voltages can be detected using the main-probe thereby allowing the user to perform single-phase voltage detection.

This instrument also features a two-button switchable load function and, as a result, is able to test 10mA or 30mA RCDs in order to determine whether they have been wired correctly. These RCD trip tests can be implemented by pressing both of the voltage tester’s operational buttons. Furthermore, by pressing both of these buttons the user places the 2100-Beta in low impedance mode which helps to improve its accuracy as it prevents ghost voltages from affecting voltage readings and detection.

Conversely, when neither of the buttons is pressed the Beha-Amprobe 2100-Beta Two Pole Voltage Tester is in high impedance mode which works to protect the user against accidentally tripping RCDs and ELCBs.

The Beha-Amprobe 2100-Beta Two Pole Voltage Tester includes a number of other safety features such as 1.5m, durable test leads, with wear indication. These test leads have two layers of insulation in two contrasting colours; this not only improves the test leads' resilience and longevity but also provides the user with a clear indication that the test lead is becoming unsafe and needs replacing when the second layer of insulation becomes visible.

Further to this, the Beha-Amprobe 2100-Beta Two Pole Voltage Tester is rugged and robust. It is constructed from reinforced components and is resistant to dust ingress and water splashes (IP64). The Beha-Amprobe 2100-Beta Two Pole Voltage Tester is built according to the standard EN 61243-3:2010; is GS approved; includes GS38 protective probe caps and has a safety rating of CAT III 690V/ CAT IV 600V.

In addition to being reliable, accurate and safe, the Beha-Amprobe 2100-Beta Two Pole Voltage Tester is also conveniently designed making it easy-to-use even within challenging environments. It includes a built-in torch allowing the user to operate this tester and perform measurements in dark environments.

Moreover, this product’s Auto-Power-Off and Auto-Power-On functions also help to ensure that this instrument is easy to operate and preserves its battery life.

Lastly, the Beha-Amprobe 2100-Beta Two Pole Voltage Tester is supplied with 4mm test probe extensions with GS38 protective probe caps (as mentioned above). Both the probe extensions and caps can be stored in the attachable test probe protector cover, which can also be used to open UK safety outlets.

All of these features make the Beha-Amprobe 2100-Beta Two Pole Voltage Tester ideal for detecting continuity and measuring voltage in a variety of commercial and industrial environments.

Beha-Amprobe 2100-Beta Two Pole Voltage Tester Key Features

  • Rugged, resilient, easy-to-use instrument optimized for detecting and measuring AC/DC voltage
  • Continuity checks
  • Two-pole phase rotation
  • Single-pole tests to indicate polarity  
  • LED light display indicates voltage range, polarity and continuity
  • LCD display indicates voltage reading
  • 12-690V AC/DC measurement range
  • Issues audible indication when the voltage detected is equal to, or greater than, 50V AC or 120V DC
  • Single-phase voltage detection using the main probe
  • Two-button switchable mode detection
  • If neither button is pressed the voltage tester is in high impedance mode, protecting the user against accidentally tripping RCDs and ELCBs
  • Pressing both buttons puts the tester in low impedance mode which works to eliminate ghost voltages
  • Pressing both buttons also allows the user to purposely trip RCDs
  • 1.5m, durable test leads, with wear indication
  • Reinforced components
  • Resistant to water splashes
  • Resistance to dust ingress
  • IP64
  • Built to EN 61243-3:2010 standard
  • GS approved
  • Safety rating: CAT III 690V/ CAT IV 600V
  • GS38 protective probe caps
  • Built-in torch
  • Auto-Power-On
  • Auto-Power-Off
  • 4mm test probe extensions
  • Attachable test probe protector cover which also opens UK safety outlets
  • Ideal for use in commercial and industrial environments

What’s Included?

  • Beha-Amprobe 2100-Beta Two Pole Voltage Tester
  • 4mm Test Probe Extensions with GS38 Protective Probe Caps
  • Test Probe Protector Cover

Beha-Amprobe 2100-Beta Two Pole Voltage Tester Technical Specifications

 2100-Alpha2100-Beta2100-Gamma

Voltage Test

LED Voltage Range

12…690 V AC/DC

12…690 V AC/DC

12…≥690 V AC/DC

LED Indicator

±12, ±24, 50, 120, 230, 400, 690 V

±12, ±24, 50, 120, 230, 400,  ≥690 V

LED Tolerances

acc. To EN 61243-3:2010

LCD Voltage Range

-

12…690 V AC/DC

6…1000 V AC/ 6…1200 V DC

LCD Resolution

-

1 V

LCD Tolerance

-

± (3% rdg + 3 LSD)

LED and LCD Response Time

< 1s

Frequency Range

DC,  16 2/3 Hz…400 Hz

Acoustic Indication

≥ 50 V AC, ≥ 120 V DC

Voltage Detection

Automatic (AC/DC)

Polarity Detection

Full Range

Range Detection

Automatic

Current I

(load buttons not activated)

≤3.5 mA AC/DC at 690 V AC/DC

≤3.5 mAAC at 1000 VAC/ 4.5 mADC at 1200 VDC

Internal Load

(load buttons not activated)

Approximately 2.4 W at 690 V AC/DC

Approximately 3.5 W at 1000 VAC / Approximately 5.4 W at 1200 VDC

Test Current Switchable Load

(load buttons activated)

≤350 mA AC/DC at 690 V AC/DC

≤300 mAAC at 1000 VAC / ≤350 mADC at 1200 VDC

Switchable Load

(load buttons activated)

Approximately 240 W at 690 V AC/DC

Approximately 300 W at 1000 VAC / Approximately 420 W at 1200 VDC

Automatic Power ON

LED: >12 V (activated load buttons)

 >24 V (w/o load buttons)

LED: >12 V (activated load buttons)

 >24 V (w/o load buttons)

LCD: >12V

LED: >12 V

LCD: > 6V

Trip Test RCD (earth leakage circuit breaker)

Test Current Switchable Load

(load buttons activated)

>30 mAAC at 230 VAC

Single Pole Phase Test

Voltage Range

180…690 VAC against earth

100…1000 VAC against earth

Frequency Range

40Hz… 70Hz

Acoustic Indication

Yes

Indication

Red LED

Continuity Test (Rx)/ Diode Test

Range

0….500 kΩ

Tolerance

0% to +50%

Test Current

<5 μA

Acoustic Indication

Yes

Diode Test

Yes

Indication

RED LED

Overvoltage Protection

690 V AC/DC

1000 VAC/ 1200 VDC

Automatic Power ON

< 500 kΩ

Phase Rotation Indication

Voltage Range

340…440 V AC phase to phase

170…1000 V AC phase to phase

Frequency Range

47…63 Hz

40…70 Hz

Indication

Red LED

Resistance Measurement (Ω)/ Low Resistance Indication (2100-Gamma only)

Resistance Range on LCD

0….1999 Ω

Resolution

1 Ω

Tolerance

± (5% rdg + 10 LSD) at 20°C

Temperature Coefficient

± (5 LSD / 10 K)

Test Current

<30 μA

Low Resistance Indication

Acoustic Indication <10…50Ω

Overvoltage Protection

690 V AC/DC

1000 VAC/ 1200 VDC

Non-Contact Voltage Indication/ Electric Field (NCV/EF)

Voltage Range

-

100…1000 VAC

Frequency Range

-

50…60 Hz

Indication

_

3 levels shown by LCD segments

Data Hold

Data Hold

_

Only voltage measurements (12…690V AC/DC)

Voltage and resistance measurements, NCV

Measurement Illumination Area/ Torch Light

Torch Light

White LED

General Specifications

Operation Time (DT)

30s

Recovery Time

240s

Operating Temperature

-15°C to +55°C

Storage Temperature

-15°C to +55°C

Humidity

Max. 95% RH

Operating Altitude

Up to 2000m

Safety Rating (Overall Voltage Category)

CAT IV / 600V, CAT III / 690V

CAT IV / 600V, CAT III / 1000V

Pollution Degree

2

Protection Degree

IP64

Safety Regulations

IEC 61243-3:2009, EN 61243-3:2010, DIN VDE 0682-401:2011

Approvals, Compliance

GS mark from TÜV Rheinland, CE

Power Supply

Battery 2 x 1.5V (AAA/ IEC LR03)

Power Consumption

Approximately 60mA

Battery Lifetime

More than 10000 measurements (<5 s/ per measurement)

Dimensions (HxWxD)

Approximately 280 x 78 x 35 mm (11.0 x 3.1 x 1.4 in)

Weight

Approximately 320 g (0.71 lb)

Amprobe 2100-Series Two Pole Voltage Tester - Datasheet Datasheets Amprobe 2100-Series Two Pole Voltage Tester - User Manual Manuals & Guides

Reviews

Additional Information
SKU 4312508
Manufacturer Part Code 4312508
Country of Origin China