The Aim-TTi TF960 6GHz Bench/ Portable Universal Counter is a frequency meter with a measurement range spanning 0.001Hz to 6000MHz. It has high input sensitivity over the entire frequency range.
The Aim-TTi TF960 6GHz Bench/ Portable Universal Counter’s high-quality, temperature-compensated internal frequency reference (TCXO) has a low ageing rate and is stable to ±1ppm over the full temperature range. It has a short warm-up time, ensuring that the Aim-TTi TF960 6GHz Bench/ Portable Universal Counter can take accurate measurements even when battery powered.
Additionally, the Aim-TTi TF960 6GHz Bench/ Portable Universal Counter will automatically swap over from the internal timebase when an external reference standard is connected to the external reference input.
To ensure a high-resolution at all frequencies, the Aim-TTi TF960 6GHz Bench/ Portable Universal Counter uses a reciprocal counting technique. It provides an eight-digit measurement in one second, a nine-digit reading in ten seconds, and a ten-digit measurement in one-hundred seconds. Ten-digit readings have a granularity of fewer than two counts in the least significant digit.
Measurements can be viewed in Hz, kHz, MHz, ns, us, ms or s on the Aim-TTi TF960 6GHz Bench/ Portable Universal Counter’s high-contrast, ten-digit display with a 12.5mm digit height. Via the display, and the Aim-TTi TF960 6GHz Bench/ Portable Universal Counter’s comprehensive array of annunciators, the user can view the input configuration and function, measurement time and status, external reference connection, and low battery indication.
The Aim-TTi TF960 6GHz Bench/ Portable Universal Counter features the following measurement functions:
The Aim-TTi TF960 6GHz Bench/ Portable Universal Counter also includes three inputs optimised for use with different frequency ranges.
Input A
Input A features configurable coupling (AC or DC), input impedance (1MΩ or 50Ω), attenuation (1:1 or 5:1), a fully variable threshold, and an active edge. It is designed for use with frequencies between 0.001Hz and >125MHz.
Input B
Designed for use with frequencies between 80MHz and >3GHz. It is a nominal 50Ω input.
Input C
Input C, like Input B, is a nominal 50Ω input; however, it also includes a standard N connector. This input is designed for use with frequencies between 1.8GHz and 6GHz.
The integrated USB interface facilitates remote control of the Aim-TTi TF960 6GHz Bench/ Portable Universal Counter using an RS-232 protocol via a computer’s USB port.
Additionally, the Aim-TTi TF960 6GHz Bench/ Portable Universal Counter supports the remote commands of its predecessor, the Aim-TTi TF830.
The Aim-TTi TF960 6GHz Bench/ Portable Universal Counter can be powered via its USB port or via its internal, rechargeable NiMH batteries. These batteries, combined with the Aim-TTi TF960 6GHz Bench/ Portable Universal Counter’s low-power consumption, provide up to twenty-four hours of operation.
The Aim-TTi TF960 6GHz Bench/ Portable Universal Counter’s NiMH batteries can be recharged in under four hours using the supplied AC charger.
The Aim-TTi TF960 6GHz Bench/ Portable Universal Counter is an ergonomic and accurate frequency meter with a wide measurement range and an integrated USB interface.