All Aim-TTi Products

Aim-TTi TF930 3GHz Bench/ Portable Universal Counter

SKU
58132-1000
Rating:
0%
(0)
Reward Points
:
362
£434.40 £362.00
Free UK Delivery*

Black Friday - Free Items With Orders Over £300

Black Friday Freebies
Spend £100 to £749.99
LED Head Torch (Worth: £15.99)

Spend Over £750
Free LED Head Torch & Extendable Flash Light (Worth: £35.98)

Prices Ex VAT
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Aim-TTi TF930 3GHz Bench/ Portable Universal Counter

The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter is a high-accuracy frequency meter. It has a 0.001Hz to 3000MHz frequency range with a high input sensitivity.

High Accuracy

The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter features a high-quality temperature-compensated internal frequency reference (TCXO). It has a low ageing rate and is stable to ±1ppm over the full temperature range.

Furthermore, the TCXO has a short warm-up time. This means accurate measurements can be determined even when the Aim-TTi TF930 3GHz Bench/ Portable Universal Counter is being used as a portable, battery-powered meter.

Moreover, when an external reference standard is connected to the Aim-TTi TF930 3GHz Bench/ Portable Universal Counter’s external reference input, it will automatically change over from the internal timebase.

High Resolution

The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter utilises a reciprocal counting technique to provide a high-resolution at all frequencies: eight-digit readings are determined in one second, nine-digit readings are determined in ten seconds, and ten-digit readings are determined in one-hundred seconds. Ten-digit measurements have a granularity of fewer than two counts in the least significant digit.

Ten-Digit LCD

Measurements are displayed on the Aim-TTi TF930 3GHz Bench/ Portable Universal Counter’s high-contrast, ten-digit display with a digit height of 12.5mm. The user can view measurements in Hz, kHz, MHz, ns, us, ms or s. The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter also includes a comprehensive set of annunciators. Between the ten-digit display and annunciators, the user can view the input configuration and function, measurement time and status, external reference connection, and low battery indicator.

Flexible Signal Conditioning

The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter features two inputs optimised for use at different frequency ranges.

Input A

Input A is designed for use with frequencies in the range 0.001Hz to >125MHz. It features configurable coupling (AC or DC), input impedance (1MΩ or 50Ω), 1:1 or 5:1 attenuation, a fully variable threshold, and an active edge.

Input B

A nominal 50Ω input for use with frequencies in the range 80MHz to >3GHz.

Multiple Measurement Functions

The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter includes the following measurement modes: Frequency, Period, Pulse Width, Duty Cycle, Frequency Ratio, and Event Counting (totalise).

USB Interface

The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter’s integrated USB interface enables remote control using an RS-232 protocol via a computer’s USB port.

The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter supports the remote commands of its predecessor, the Aim-TTi TF830.

Battery Operation

To enable portability and use in remote locations, the Aim-TTi TF930 3GHz Bench/ Portable Universal Counter can be battery powered. Internal rechargeable NiMH batteries provide up to twenty-four hours of power and can be recharged within four hours using the supplied AC charger.

Alternatively, the Aim-TTi TF930 3GHz Bench/ Portable Universal Counter can be powered via the integrated USB port.

The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter is a high-quality, high-accuracy, high-resolution frequency meter with a USB interface.

Aim-TTi TF930 3GHz Bench/ Portable Universal Counter Key Features

  • A high-accuracy frequency meter
  • Frequency range: 0.001Hz to 3000MHz
  • High input sensitivity over the entire frequency range
  • High-quality, temperature-compensated internal frequency reference (TCXO)
  • Low ageing rate
  • Stable to ±1ppm over the full temperature range
  • Short warm-up time: ensures accurate measurements even when battery-powered
  • External reference input
  • Automatically switches when an external reference standard is connected to the external reference input
  • Reciprocal counting technique provides a high resolution at all frequencies
  • Eight-digit readings are determined in one second
  • Nine-digit readings are determined in ten seconds
  • Ten-digit readings are determined in one-hundred seconds
  • Ten-digit measurements have a granularity of fewer than two counts in the least significant digit
  • High-contrast, ten-digit display with a 12.5mm digit height
  • View measurements in Hz, kHz, MHz, ns, us, ms or s
  • A comprehensive set of annunciators
  • View the input configuration and function, measurement time and status, external reference connection, and low battery indicator
  • Two inputs optimised for use at different frequency ranges: Input A and Input B
  • Measurement modes: Frequency, Period, Pulse, Width, Duty Cycle, Frequency Ratio, and Event Counting (totalise)
  • USN interface for remote control using an RS-232 interface via a computer’s USB port
  • Supports the remote commands of its predecessor, the Aim-TTi TF830
  • Battery-powered: internal rechargeable NiMH batteries provide up to twenty-four hours of power
  • Internal batteries can be recharged in less than four hours using the supplied AC charger
  • Can be powered via the integrated USB port
  • A high-quality, high-accuracy, high-resolution frequency meter with a USB interface

What’s Included?

  • Aim-TTi TF930 3GHz Bench/ Portable Universal Counter
  • 3x Internal 2500mAh NiMH Batteries
  • AC Charger

Reviews

Additional Information
SKU 58132-1000
Manufacturer Part Code 58132-1000