Aim-TTi TF930 3GHz Bench/ Portable Universal Counter

All Aim-TTi Products
  • Frequency range: 0.001Hz to 3000MHz
  • Frequency, Period, Pulse, Width, Duty Cycle, Frequency Ratio, and Event Counting modes
  • High-contrast, ten-digit display with a 12.5mm digit height
SKU
58132-1000
MPN
58132-1000

Read More

View All Frequency Counters

The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter is a high-accuracy frequency meter. It has a 0.001Hz to 3000MHz frequency range with a high input sensitivity.

High Accuracy

The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter features a high-quality temperature-compensated internal frequency reference (TCXO). It has a low ageing rate and is stable to ±1ppm over the full temperature range.

Furthermore, the TCXO has a short warm-up time. This means accurate measurements can be determined even when the Aim-TTi TF930 3GHz Bench/ Portable Universal Counter is being used as a portable, battery-powered meter.

Moreover, when an external reference standard is connected to the Aim-TTi TF930 3GHz Bench/ Portable Universal Counter’s external reference input, it will automatically change over from the internal timebase.

High Resolution

The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter utilises a reciprocal counting technique to provide a high-resolution at all frequencies: eight-digit readings are determined in one second, nine-digit readings are determined in ten seconds, and ten-digit readings are determined in one-hundred seconds. Ten-digit measurements have a granularity of fewer than two counts in the least significant digit.

Ten-Digit LCD

Measurements are displayed on the Aim-TTi TF930 3GHz Bench/ Portable Universal Counter’s high-contrast, ten-digit display with a digit height of 12.5mm. The user can view measurements in Hz, kHz, MHz, ns, us, ms or s. The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter also includes a comprehensive set of annunciators. Between the ten-digit display and annunciators, the user can view the input configuration and function, measurement time and status, external reference connection, and low battery indicator.

Flexible Signal Conditioning

The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter features two inputs optimised for use at different frequency ranges.

Input A

Input A is designed for use with frequencies in the range 0.001Hz to >125MHz. It features configurable coupling (AC or DC), input impedance (1MΩ or 50Ω), 1:1 or 5:1 attenuation, a fully variable threshold, and an active edge.

Input B

A nominal 50Ω input for use with frequencies in the range 80MHz to >3GHz.

Multiple Measurement Functions

The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter includes the following measurement modes: Frequency, Period, Pulse Width, Duty Cycle, Frequency Ratio, and Event Counting (totalise).

USB Interface

The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter’s integrated USB interface enables remote control using an RS-232 protocol via a computer’s USB port.

The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter supports the remote commands of its predecessor, the Aim-TTi TF830.

Battery Operation

To enable portability and use in remote locations, the Aim-TTi TF930 3GHz Bench/ Portable Universal Counter can be battery powered. Internal rechargeable NiMH batteries provide up to twenty-four hours of power and can be recharged within four hours using the supplied AC charger.

Alternatively, the Aim-TTi TF930 3GHz Bench/ Portable Universal Counter can be powered via the integrated USB port.

The Aim-TTi TF930 3GHz Bench/ Portable Universal Counter is a high-quality, high-accuracy, high-resolution frequency meter with a USB interface.

Aim-TTi TF930 3GHz Bench/ Portable Universal Counter Key Features

  • A high-accuracy frequency meter
  • Frequency range: 0.001Hz to 3000MHz
  • High input sensitivity over the entire frequency range
  • High-quality, temperature-compensated internal frequency reference (TCXO)
  • Low ageing rate
  • Stable to ±1ppm over the full temperature range
  • Short warm-up time: ensures accurate measurements even when battery-powered
  • External reference input
  • Automatically switches when an external reference standard is connected to the external reference input
  • Reciprocal counting technique provides a high resolution at all frequencies
  • Eight-digit readings are determined in one second
  • Nine-digit readings are determined in ten seconds
  • Ten-digit readings are determined in one-hundred seconds
  • Ten-digit measurements have a granularity of fewer than two counts in the least significant digit
  • High-contrast, ten-digit display with a 12.5mm digit height
  • View measurements in Hz, kHz, MHz, ns, us, ms or s
  • A comprehensive set of annunciators
  • View the input configuration and function, measurement time and status, external reference connection, and low battery indicator
  • Two inputs optimised for use at different frequency ranges: Input A and Input B
  • Measurement modes: Frequency, Period, Pulse, Width, Duty Cycle, Frequency Ratio, and Event Counting (totalise)
  • USN interface for remote control using an RS-232 interface via a computer’s USB port
  • Supports the remote commands of its predecessor, the Aim-TTi TF830
  • Battery-powered: internal rechargeable NiMH batteries provide up to twenty-four hours of power
  • Internal batteries can be recharged in less than four hours using the supplied AC charger
  • Can be powered via the integrated USB port
  • A high-quality, high-accuracy, high-resolution frequency meter with a USB interface

What’s Included?

  • Aim-TTi TF930 3GHz Bench/ Portable Universal Counter
  • 3x Internal 2500mAh NiMH Batteries
  • AC Charger
£373.00
£447.60 inc vat
Free Delivery*
Important Notice
This item is made-to-order exclusively for you once your order is placed. As a result, it is not eligible for cancellation or return under our standard policy. Your statutory rights remain unaffected.
373 Reward Points 60 Days Return

Ask An Expert
Price Match
Technical Information
Additional Information
SKU
58132-1000
Manufacturer Part Code
58132-1000

Customer Reviews

Accessories

Product
SKU
MPN
Price (Ex VAT)
Aim-TTi RM50A 2U Bench Instruments Rack Mount
51200-0280
51200-0280
£82.00
Aim-TTi UAC-B Universal AC Adaptor
51151-0830
51151-0830
£18.00
 
Aim-TTi TF930 3GHz Bench/ Portable Universal Counter
£373.00
£447.60 inc vat
£373.00
£447.60 inc vat