All Aim-TTi Products

Aim-TTi PSA3605 Handheld RF Spectrum Analyser (3.6GHz)

SKU
58350-2300
Rating:
0%
(0)
Reward Points
:
1859
£2,230.80 £1,859.00
Free UK Delivery*

Black Friday - Free Items With Orders Over £300

Black Friday Freebies
Spend £100 to £749.99
LED Head Torch (Worth: £15.99)

Spend Over £750
Free LED Head Torch & Extendable Flash Light (Worth: £35.98)

Prices Ex VAT
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Aim-TTi PSA3605 Handheld RF Spectrum Analyser

The Aim-TTi PSA3605 Handheld RF Spectrum Analyser is a portable radio frequency analyser with a frequency range of 10MHz to 3600MHz.

It supports resolution bandwidths between 300Hz and 10MHz (1:3:10) and has a typical noise floor of -120dBm at -40dBm ref. level/ 10kHz RBW. It also includes a selection of analytical functions, modes and tools: the Aim-TTi PSA3605 Handheld RF Spectrum Analyser features a frequency counter with a 10Hz resolution, frequency presets, and Smart Marker movement with selectable peak tracking. It is also equipped with an Auto-Find function, which automatically sets sweep parameters according to the highest detected signal; a Zero Span mode with AM and FM audio demodulation, and the following trace modes:

  • Normal
  • Peak Hold
  • Average

Live, View, and Reference traces are displayed in contrasting colours on the Aim-TTi PSA3605 Handheld RF Spectrum Analyser’s 4.3” TFT touchscreen display. Additionally, measurements can be displayed in either dBm or dBµV, mV or µW. Via the display, the user can also view twin markers with readouts of the absolute and difference values.

The Aim-TTi PSA3605 Handheld RF Spectrum Analyser features a 1.8GB memory to which frequency presets, state files, waveforms, setups and screens can be saved. The Aim-TTi PSA3605 Handheld RF Spectrum Analyser offers unlimited storage of waveforms, set-ups and screens as it includes USB interfaces for Flash drives and PC connection. Files can be saved under user-specified names and with time-stamps determined using the Aim-TTi PSA3605 Handheld RF Spectrum Analyser’s real-time clock.

To improve ease-of-operation, the Aim-TTi PSA3605 Handheld RF Spectrum Analyser features comprehensive status and context-sensitive help screens. Other practical features include a rechargeable lithium-ion battery capable of providing over three hours of operating time.

The Aim-TTi PSA3605 Handheld RF Spectrum Analyser is a compact, lightweight (0.56kg) and comprehensive radio frequency spectrum analyser.

Aim-TTi PSA3605 Handheld RF Spectrum Analyser Key Features

  • Portable radio frequency analyser
  • Frequency range: 10MHz to 3600MHz
  • Resolution bandwidths between 300Hz and 10MHz (1:3:10)
  • -120dBm typical noise floor at -40dBm ref. level/ 10kHz RBW
  • Frequency counter with 10Hz resolution
  • Frequency presets
  • Smart marker movement with selectable peak tracking
  • Auto-Find function: automatically sets sweep parameters according to the highest detected signal
  • Zero Span mode with AM and FM audio demodulation
  • Trace modes: Normal, Peak Hold, Average
  • Live, View and Reference traces are displayed in contrasting colours
  • 4.3” TFT touchscreen display
  • View measurements in dBm or dBµV, mV or µW
  • Twin markers with readouts of absolute and difference values
  • 1.8GB memory
  • USB interfaces for Flash Drives and PC connection
  • Unlimited storage of waveforms, set-ups and screens
  • Files can be saved under user-specified names
  • Files can be time-stamped
  • Real-time clock
  • Comprehensive status and context-sensitive help screens
  • Rechargeable lithium-ion battery: provides over three hours of continuous operating time
  • Weight: 0.56kg
  • Compact, lightweight and comprehensive radio frequency spectrum analyser

What’s Included?

  • Aim-TTi PSA3605 Handheld RF Spectrum Analyser

Aim-TTi PSA3605 Handheld RF Spectrum Analyser Technical Specifications 

Frequency Measurement 
Frequency Span Frequency Range 10 MHz to 3600 MHz
Setting Modes Centre frequency plus Span, or Start plus Stop frequencies
Maximum Span 3590 MHz
Minimum Span 27 kHz, or Zero Span with demodulation
Set. Resolution 100 Hz at any frequency
Setting Accuracy Reference Frequency Accuracy for Start, Stop & Centre (Zero-Span) frequencies
Reference Frequency Accuracy Initial Accuracy Better than ± 1 ppm at 20°C
Stability Better than ± 1 ppm over 10°C to 30°C
Ageing Better than ± 1 ppm per year
Phase Noise (Typical) Carrier at 1 GHz -83 dBc/Hz at 30 kHz offset
-99 dBc/Hz at 100 kHz offset
-116 dBc/Hz at 1 MHz offset
Carrier at 3 GHz -94 dBc/Hz at 30 kHz offset
-109 dBc/Hz at 100 kHz offset
-117 dBc/Hz at 1 MHz offset
Carrier at 6 GHz -83 dBc/Hz at 30 kHz offset
-97 dBc/Hz at 100 kHz offset
-114 dBc/Hz at 1 MHz offset
Resolution Bandwidth RBW Selectable between 10 MHz and 300 Hz, selectable in 1:3:10 sequence, or Auto
Video Filtering Selectable between 10 MHz and 300 Hz, selectable in 1:3:10 sequence, or RBW Tracking
Markers  No. of Markers One, Two (or None)
Resolution 0.1 kHz at all frequencies
Marker Accuracy 1/270th of Span ± 10Hz plus reference frequency accuracy
Readout The frequencies at the marker points and the frequency difference are displayed
Functions Normal (Scroll Mode), Peak Find Mode, Peak Track Mode, Frequency Measurement
Marker Frequency Counter Note Frequency counted at the current active marker (M1 or M2) in
sweep or zero-span mode
Resolution 10Hz, 100Hz or 1kHz
Accuracy Reference frequency accuracy +/- 1 count for signal > noise level +25dB
Amplitude Measurement 
Amplitude Range Units Selectable as dBm or dBµV
Display Range 84 dB from the reference level
Magnification x2, x5 or x10
Reference Level Selectable between -40dBm and +20 dBm
(67dBµV to 127dBµV) in 1dB steps
Amplitude Accuracy Calibration Level Accuracy Better than ± 1 dB at 10dB below ref. level @ 2000MHz (20°C ± 5°C)
Flatness Better than ± 1 dB relative to 2000MHz over the full operating frequency range
Linearity Better than ± 1 dB over 60dB range down from the reference level
Markers No. of Markers One, Two (or None)
Resolution 0.1 dB
Readout The level at the marker points and
the difference are displayed.
Displayed Units dBm, dBuV, mV or uW
Functions Normal (Scroll Mode), Peak Find Mode, Peak Track Mode, Frequency Measurement
Displayed Average Noise Level (DANL) DANL Better than – 120 dBm (-13 dBuV) average displayed noise floor (ref. level = – 40 dBm RBW = 10 kHz, VBW = 1 kHz, span 1 MHz) for frequency range 10MHz to 5.5GHz
Noise per Hz Better than -160 dBm/Hz equivalent
Distortion and Spurii 3rd Order Intermodulation < –60dBc for two signals at 10dB below reference level, (500MHz and 502MHz) ; typically < -65dBc
Harmonic < –60dBc at 10dB below reference level (100MHz)
Signal Images <– 55dBc, typically <– 60dBc in ‘Normal’ image rejection mode
for RBWs between 300Hz and 3MHz
Other Signal Related Spurii <-60 dBc for signals 10 dB below the reference level
Residual Spurii <-70 dB below the reference level
Signal Input 
Input Connector N Type, 50Ω
VSWR 1.5 : 1 typical
Maximum Level + 25 dBm, (132 dBµV); +/-50V DC
Sweep
Sweep Method Detection for 271 points per sweep. The amplitude value (as determined by the detection mode) from each sub-span is stored (sub-span = span/270)
Signal Detection Modes Alternate Peak (default), Positive Peak, Negative Peak, Sample, Linear Average, Log Average or RMS
Signal Image Rejection Modes Real-time rejection with automatic or manual re-alignment or Data Comparison based rejection.
Sweep Time Sweep time is an automatic function of Span and RBW/VBW. A speed-up function enables the time to be reduced by a factor of up to ten.
Sweep Modes Repeat (continuous) or Single Shot
Demodulation (Zero Span Mode)
Audio Demodulation Modes AM or FM
Internal Audio Internal loudspeaker with adjustable volume and mute.
Audio Out 30 mW into 32 W mono or stereo headphones, adjustable volume, 3.5mm jack socket
Audio Filter Switchable 3kHz Low Pass Filter.
Carrier Display Horizontal line at carrier level.
Display & Traces 
Display Type 4.3 inch (10.9 cm) backlit TFT LCD, 480 x 272pixels total, 16 colours, resistive touch screen.
Graticule 8.5 x 10 divisions, light grey graticule.
Displayed Points 271 points per sweep.
Live Trace Dot-joined trace from current sweep.
Trace Modes Normal (overwrite), Peak Hold, or Average
(2 to 48 sweeps).
View Trace Buffered “instance” of the live trace
Reference Trace Stored trace recalled from a trace file
Dual Trace Mode For Peak Hold and Average modes, processed and un-processed traces can be displayed simultaneously
Memory Storage 
Internal Disk 1.8GB of internal memory
External Storage USB host interface for removable USB Flash drives.
Store Trace Up to 999 traces can be stored under either default file names or user entered file names. Traces are stored as tables of amplitude versus frequency and can be imported into other programs, as well as being recalled to the screen.
Recall Trace Recalls any stored trace to the reference trace of the display.
Store Set-up Up to 999 instrument set-ups can be stored under either default file names or user-entered file names. All settings of the instrument are saved.
Recall Set-up Recalls any stored set-up, overwriting the existing settings of the instrument.
Store Screen This function copies the whole screen area to memory as a bit-map. Up to 999 screens can be stored under either default file names or user-entered file names.
Recall Screen Recalls any stored screen as an image
Connectors 
RF Input Standard N Type connector.
DC Power 1.3 mm power socket for external power supply/charger
USB Host Standard USB type A connector for connection of USB Flash drives.
USB Device Mini USB connector for connection to a PC.
Audio Out 3.5 mm jack socket for demodulated audio out (accepts mono or stereo plugs).
Power Sources 
Battery Battery Type Li-ion 3.7V 3000mA-hr
Battery Life Greater than 3 hours continuous
Recharge Time < 3 hours from fully discharged
Auto Off Mode To conserve battery life, the system can be set to automatically
switch off after a defined time from the last key press. This can be set between 5 mins and 60 mins (or never).
Battery Status Multi-segment battery status indicator.
AC Line Operation/Charging Note The instruments can be operated continuously from mains power
using the AC line adaptor provided. This powers and recharges the
instrument simultaneously
Voltage Range 100V to 240V nominal 50Hz/60Hz
Mechanical 
Size 192mm high x 92mm wide x 49mm deep (height excludes RF input connector)
Weight 580 grms
Tilt Stand Built-in tilt stand for bench use which angles the unit at 40 degrees to the horizontal.
Stylus Casing incorporates plug-in stylus
Environmental & Safety 
Operating Range +5°C to + 40°C, 20% to 80% RH.
Storage Range -10°C to +50°C
Environmental Indoor use at altitudes to 2000m, Pollution Degree 2.
Electrical Safety Complies with EN61010-1.
EMC Complies with EN61326.
Accessories related to this product:

Reviews

Additional Information
SKU 58350-2300
Manufacturer Part Code 58350-2300