All Aim-TTi Products

Aim-TTi LCR400 LCR Meter

SKU
58123-0010
Rating:
0%
(0)
Reward Points
:
956
£1,147.20 £956.00
Free UK Delivery*
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Aim-TTi LCR400 LCR Meter

The Aim-TTi LCR400 LCR Meter is a high-accuracy and economical inductance, capacitance and resistance meter. It has a maximum measurement frequency of 10kHz and a measurement accuracy of 0.1%.

Innovative and Ergonomic Design

Rugged and weighted to ensure it remains still during testing, the Aim-TTi LCR400 LCR Meter includes two high-brightness, five-digit displays and the latest component technologies. It features a four-terminal sprung-jaw test fixture with adaptors for axial or radial components. This fixture is unobstructed to enable easy use with bandoliers.

Alternative Connection Methods

To facilitate connection to external test fixtures, the Aim-TTi LCR400 LCR Meter can be used with OPTIONAL adapters. For example, it can be used with an adapter to convert the test fixture into four BNC sockets enabling the connection of external test fixtures and test lead sets.

Similarly, the Aim-TTi LCR400 LCR Meter can be used with an OPTIONAL Kelvin Clip test lead set to facilitate four-terminal measurements. Alternatively, it can be used with SMD tweezers to measure surface mount components. The surface mount tweezers are connected directly into the Aim-TTi LCR400 LCR Meter’s four-terminal test fixture.

Full Component Sorting

The Aim-TTi LCR400 LCR Meter automatically recognises components and will sort them into ‘bins’ according to their measurements. The ‘bin’ parameters can be configured via the Aim-TTi LCR400 LCR Meter’s keyboard or on a PC and uploaded via the RS-232 interface. The user can specify the parameters for up to eight pass bins and two fail bins. Bin limits can be based around different nominals or a single nominal and can be configured to be sequential or overlapping. 

Non-Volatile Memory

Up to nine setups can be saved to the Aim-TTi LCR400 LCR Meter’s non-volatile memory enabling rapid-recall. In addition to this, the Aim-TTi LCR400 LCR Meter will remember the last used setup.

Automated Results Logging

The RS-232 interface allows the Aim-TTi LCR400 LCR Meter to be connected to a PC. Using this interface and the OPTIONAL Windows-based Aim-TTi LCR-PCLink Software, results can be logged to the PC where they are saved into a file and displayed on the screen. Additionally, this software and interface can be used to save and restore instrument set-ups.

The Aim-TTi LCR400 LCR Meter is a cost-effective, precise and adaptable inductance, capacitance and resistance meter. It is optimised for use in laboratories, and component inspection and production facilities.

Aim-TTi LCR400 LCR Meter Key Features

  • High-accuracy and economical inductance, capacitance and resistance meter
  • Maximum measurement frequency: 10kHz
  • Measurement accuracy: 0.1%
  • Rugged
  • Weighted to ensure it remains in place during testing
  • Two high-brightness, five-digit displays
  • Latest component technology
  • Four-terminal, sprung-jaw test fixture with adapters for axial or radial components
  • The test fixture is unobstructed for easy use with bandoliers
  • Use with OPTIONAL adapters to enable connection to external test fixtures
  • The test fixture can be converted into four BNC sockets using an OPTIONAL adapter
  • Use with an OPTIONAL Kelvin clip test lead set to enable four-terminal measurements
  • Use with OPTIONAL SMD tweezers to measure surface mount components
  • Automatically recognises components
  • Sorts components into pass/ fail bins according to their measurements
  • Specify the parameters for up to eight pass bins and two fail bins
  • Bin limits can be based around different nominals
  • Bin limits can be sequential or overlapping from a single nominal
  • Configure bin parameters via the keyboard
  • Configure bin parameters on a PC and upload them via the RS-232 interface
  • Non-volatile memory: save up to nine setups
  • Remembers the last setup used
  • Use the RS-232 interface and OPTIONAL Aim-TTi LCR-PCLink Software to log results
  • Use the RS-232 interface and OPTIONAL Aim-TTi LCR-PCLink Software to save and restore instrument setups
  • Cost-effective, precise and adaptable inductance, capacitance and resistance meter
  • Optimised for use in laboratories, and component inspection and production facilities

What’s Included?

  • Aim-TTi LCR400 LCR Meter

Aim-TTi LCR400 LCR Meter Technical Specifications

Measurement Functions 
Parameters Measured R, L, C, D, & Q
Parameter Selection Manual or automatic selection of R, L or C.
Measurement Modes Series or parallel equivalent circuit.
Range Hold Prevents autoranging when changing components
Zero Function Nulls out up to 100pF at test fixture
Measurement Freq Selectable as 100Hz/120Hz, 1kHz, 10kHz
Displayed Functions R+Q, L+Q, C+D, C+R
Measuring Ranges 
Resistance 0.1m to 990M    
Inductance 0.001µH to 9900H    
Capacitance 0.001pF to 99000µF    
D 0.001 to 999    
Q 0.001 to 999    
Accuracy Limits 100Hz 1kHz 10kHz
R 0.1% ± 1 digit 2-1MΩ 2-500kΩ 2-50k
0.5% ± 1 digit 0.4-5MΩ 0.4-2MΩ 0.4-200k
2% 1 digit 0.1-20MΩ 0.1-10MΩ 0.1-500k
L 0.1% ± 1 digit 4mH-500H 0.4mH-50H 40µH-5H
0.5% ± 1 digit 0.8mH-2500H 80µH-250H 8µH-25H
2% ± 1 digit 0.2mH-9900H 20µH-1000H 2µH-100H
C 0.1% ± 1 digit 10nF-1000µF 1nF-100µF 100pF-10µF
0.5% ± 1 digit 2nF-5000µF 200pF-500µF 20pF-50µF
2% ± 1 digit 500pF-20000µF 50pF-2000µF 5pF-200µF
Notes (R accuracies apply for Q<0.1. L accuracies apply for Q>10.
C accuracies apply for D<0.1 and after Null).
Limits Comparator 
Limits Set-up Multiple Upper and Lower limits can be set from keyboard or from RS-232 interface
Binning Up to 8 Pass bins can be defined plus Fail on minor parameter and general Fail.
Component Connection 
Component Connection 4-terminal connection via internal fixture for both radial and axial components. External 4-terminal connection via adaptor
Internal Fixture Sprung jaws for vertical lead insertion. Plug-in sliding pillars for horizontal lead insertion.
Bias Voltage Switchable 2V polarising voltage. External bias up to 50V can be applied.
Protection Can withstand charged capacitors up to 50V and up to 1 Joule of total energy
Display
Display Type Dual 5-digit 0.56” LEDs
Annunciators LED annunciators for all functions and measurement units
Displayed Functions R+Q, L+Q, C+D, C+R, PASS/FAIL, Bin No.
Digital Interface 
Interface Type RS-232 via 9 pin D connector, 9600 baud
Interface Function Full command and readback capability
General
Keyboard Full numeric keyboard
Non-volatile memory Up to 9 complete set-ups
Input Voltage 230V or 115V ±14%, 50/60Hz, internally adjustable, 25VA max. Installation Category ll.
Temperature Range +5°C to 40°C operating 20 - 80% RH,
-40°C to 70°C storage.
Safety Complies with EN61010-1.
EMC Complies with EN61326.
Size 360 x 240 x 95 mm including feet.
Weight 2.9kg.
Optional Accessories   
SMD Tweezers Four terminal tweezers for measuring surface mount components. Connects directly into standard test fixture.
BNC Adaptor Plugs into the standard component fixture to convert it into a set of four BNC connectors. Supplied complete with four BNC to BNC leads.
Kelvin Clip Leads High-quality Kelvin Clip test lead set terminating in BNC plugs (requires BNC adaptor).
LCR PC-Link Windows-based software which uses the RS232 interface to provide results logging and
to store/restore instrument set-ups.

 

Aim-TTi LCR400 LCR Meter - Datasheet Datasheets Aim-TTi LCR400 LCR Meter - Instruction Manual Manuals & Guides

Reviews

Additional Information
SKU 58123-0010
Manufacturer Part Code 58123-0010