Aim-TTi HA1600A Power and Harmonics Analyser
The Aim-TTi HA1600A Power and Harmonics Analyser is an efficient, easy-to-use harmonics and flicker analyser that can also be used as a mains analyser. It can measure power, voltage, current and phase angle.
Intended primarily for harmonic and flicker compliance quality measurements, the Aim-TTi HA1600A Power and Harmonics Analyser is also equipped with a UK, Schuko or USA power connector/ plug to enable general-purpose mains analysis according to relevant national standards. Please see the table below for an overview of the models available.
SKU | Name | Power Connector/ Plug |
58360-0650 | Aim-TTi HA1600A PQA with UK Plug | UK Power Connector |
58360-0660 | Aim-TTi HA1600A PQA with Schuko Plug | Schuko Power Connector |
58360-0670 | Aim-TTi HA1600A PQA with USA Plug | USA Power Connector |
Additionally, the Aim-TTi HA1600A Power and Harmonics Analyser features a large, high-resolution graphical display for continuous real-time analysis, as well as a printer interface for record-keeping and archiving, and RS-232 and USB interfaces for connection to a PC. The Aim-TTi HA1600A Power and Harmonics Analyser is also supplied with Aim-TTi’s HA-PC Link Plus Software (see below).
High-Performance Power Analyser
The Aim-TTi HA1600A Power and Harmonics Analyser is an accurate and fast AC power analyser. It can analyse single-phase loads up to 16 amps RMS and will measure watts, VA, volts RMS, volts peak, amps RMS, amps peak, crest factors, THD, power factor, frequency and inrush current.
Readings for multiple parameters are visible simultaneously on the large display. The user can also view graphical representations of voltage and current waveforms.
To provide a wide dynamic range, the Power and Harmonics Analyser includes dual, 16-bit analogue to digital converters that will continually sample both the voltage and the current. It also includes advanced algorithms to provide accurate results, and a fast Digital Signal Processor to enable real-time analysis.
Additionally, dual power cables mean the supply to the load can be kept independent of the supply to the instrument. The mounted mains connector (UK, Schuko or USA) on the front panel supplies the output to the load.
Compliance-Quality Harmonics Analyser
It can measure harmonics between the 1st and 40th quickly and simply. Tabular and histogram displays of the harmonics are updated in real-time.
Using a normal mains supply, the Aim-TTi HA1600A Power and Harmonics Analyser is suitable for conducting pre-compliance measurements. In addition to this, when used with Aim-TTi’s AC1000A Low Distortion Power Source, the Aim-TTi HA1600A Power and Harmonics Analyser can be used to conduct full compliance measurements in accordance with EN61000-3-2.
It is compliant with the 1995 and 2000 versions of the EN61000-3-2 standard and provides continuous monitoring of the supply voltage, continuous automatic calculation of harmonic limits, and supports timed test sequences with analysis of fluctuating harmonics.
Compliance-Quality Flicker Meter
The Aim-TTi HA1600A Power and Harmonics Analyser functions as a compliance-quality flicker and fluctuations meter. It is compliant with EN61000-3-3 and EN61000-4-15.
Long-term (Plt) and short-term (Pst) flicker severity can be measured using the analysis periods defined in various national standards. It will also perform a full analysis of voltage variations which includes calculation of the maximum value dmax, the difference between steady states dc, and the change of characteristic d(t). It includes an option for a current measurement method which eliminates the need for a reference impedance. This method can be used as an alternative to voltage measurements.
Aim-TTi HA-PC Link Plus Software
This Windows-based software can be used to assist with taking routine compliance measurements and archiving the results. It features RS-232 and USB interfaces.
Key Features
- An efficient, easy-to-use harmonics, flicker and mains analyser
- Measure power, voltage, current and phase angle
- Intended primarily for harmonic and flicker compliance quality measurements
- Can be used as a general-purpose mains analyser due to the inclusion of a power connector/ plug
- Three models available equipped with either a UK, Schuko or USA power connector/ plug
- Large, high-resolution graphical display for continuous real-time analysis
- Printer interface for record-keeping and archiving
- RS-232 and USB interfaces for connection to a PC
- Accurate and fast AC power analyser for single-phase loads up to 16 amps RMS
- Measures watts, VA, volts RMS, volts peak, amps RMS, amps peak, crest factors, THD, power factor, frequency and inrush current
- View readings for multiple parameters simultaneously on the display
- View graphical representations of voltage and current waveforms
- Dual, 16-bit analogue to digital converters sample both the voltage and current to provide a wide, dynamic range
- Advanced algorithms provide accurate results
- Fast Digital Signal Processor enables real-time analysis
- Dual power cables mean supply to the load can be kept separate from supply to the instrument
- Mounted mains connector supplies output to the load
- Measure harmonics between the 1st and 40th quickly and simply
- Tabular and histogram displays are updated in real-time
- Use with a mains supply to conduct pre-compliance measurements
- Use with Aim-TTi’s AC1000A Power Source to conduct full compliance measurements in accordance with EN61000-3-2
- Compliant with the 1995 and 2000 versions of the EN61000-3-2 standard
- Continuous monitoring of the supply voltage
- Continuous automatic calculation of harmonic limits
- Supports timed test sequences with analysis of fluctuating harmonics
- Compliance-quality flicker and fluctuations meter
- Compliant with EN61000-3-3 and EN61000-4-15
- Plt and Pst flicker severity can be measured using analysis periods defined in national standards
- Performs full analysis of voltage variations
- Calculation of the maximum value dmax
- Calculation of the difference between steady states dc
- Calculation of the change of characteristic d(t)
- Option for a current measurement method which eliminates the need for reference impedance
- Supplied Aim-TTi HA-PC Link Plus Software
- A fast, accurate and simple AC power, harmonics and flicker analyser
What’s Included?
- Aim-TTi HA1600A Power and Harmonics Analyser
- Aim-TTi HA-PC Link Plus Software
- PASS Power Bank & Magnetic Wireless Charger (10 000mAh 15W) - PASSPOWER-PLUS, typically £49.00
Aim-TTi HA1600A Power and Harmonics Analyser Technical Specifications
Measurement Circuit | Single Phase with standard mains connector |
Current Rating | 16A rms continuous, or national connector rating if lower |
Voltage Ranges | 115V (±200V pk) 230V (±400V pk) |
Current Ranges | ±24mA pk to ±400A pk in fifteen 2:1 ranges. |
Frequency Range | 43 - 67 Hz. |
Shunt Resistance | 3mΩ |
Sampling Rate | 300 points per cycle |
Basic Accuracy | Better than 0.2% ±1mA, up to 16A |
Measured Parameters | Vrms, Vpk, Arms, Apk, Crest factors, THD, W, VA, Power factor, Frequency, Inrush current. |
Display Modes | Tabular display of all parameters including latest and highest inrush current. Waveform graph display of voltage and current with normal, max hold, accumulate and multiple cycle display |
Monitor Outputs | Re-constructed Voltage and Current Signals. |
Harmonics Analyser | |
Measurements | 1st harmonic to 40th harmonic. |
Measurement processing for both 1995 and 2000 Editions of EN61000-3-2. Continuous calculation, analysis and assessment of unfiltered, filtered, average, minimum and maximum current harmonic levels and limits. Continuous measurement and assessment of supply waveform and harmonics. |
|
Current Rating | 16A rms continuous, or national connector rating if lower |
Voltage Ranges | 115V (±200V pk) 230V (±400V pk) |
Current Ranges | ±24mA pk to ±400A pk in fifteen 2:1 ranges |
Frequency Range | 43 - 67 Hz |
Shunt Resistance | 3mΩ. |
Transforms Window | Continuous 4, 10, 12 or 16 cycle Discrete Fourier Transforms |
Basic Accuracy | Better than 5% of limit or 0.2% of selected range (whichever is the greater) ± 1mA. |
Display Modes | Display of load supply assessment for voltage, harmonics, crest limits and frequency against requirements of EN61000-3-2. Histogram or tabular display of supply voltage harmonics. Histogram display of current harmonics with limits, Min. hold, Max. hold and percentage of limit display options. Tabular display of current harmonics showing present values, limits, average values, average as percent of limit, maximum values, maximum as percent of limit and pass or fail assessment for each harmonic. |
Test Control | Untimed, manually timed or automatically timed tests; user-defined test time. Limits automatically determined from EN61000-3-2 for appropriate class; Class C and Class D limits can be automatically calculated from power measurements or from ratings declared by the user. Minimum and maximum power thresholds for limits can be changed by the user. Facility for declaring supply voltages other than 230V and deriving appropriate limits. Facility for insetting test limits. |
Report Printing | Direct printer connection for hard-copy report with user-entered narrative, supply voltage assessment and current harmonic analysis and assessment. |
Voltage Fluctuations & Flicker Meter | |
Measurements | Voltage fluctuations dmax, dc, d(t) and flicker Pst and Plt to EN61000-3-3 and EN61000-4-5. |
Current Rating | 16A rms continuous, or national connector rating if lower |
Voltage Ranges | 115V (±200V pk) 230V (±400V pk) |
Fluctuation Range | 25% max. (relative to nominal voltage) |
Flickermeter Range | Voltage change up to 20% (sinewave change) or 10% (low repetition rate rectangular change) relative to AGC level. Equivalent to 6400 pu on 8.8 Hz sinewave. |
Flickermeter AGC | Up to ± 5% |
Flickermeter Accuracy | Better than 5% for Pst range 0·7 to 10·0 |
Frequency Range | 50 or 60 Hz (operates over 43 – 67 Hz) |
Report Printing | Tabular listing of voltage variations, Pst classifier and Pst in each Plt interval. |
General | |
Display | 320 x 240 pixel backlit LCD. |
Clock | Realtime clock for time/date stamping of Report data |
Interfaces | Parallel Printer, RS-232, USB |
Instrument Supply | 230V or 115V ±14%, 48 to 65Hz |
Operating Range | +5°C to 40°C, 20-80% RH. |
Storage Range | –10°C to +60°C |
Dimensions | 357 x 132 x 235mm (WxHxD) |
Weight | 4.4 kg |
Safety | Complies with EN61010-1 |
EMC Compliance | Complies with EN61326-1 |
HA-PC Link Plus Software | |
HA-PC Link Plus Software | HA-PC LINK PLUS is PC (Windows) software supplied with the HA1600A. It can communicate with the instrument through either an RS232 or a USB connection. It is intended to assist users in taking routine compliance measurements and archiving the results. The PC is used for configuration, display and data archiving only; all real time data handling and measurement processing continues to be performed by the Digital Signal Processor in the instrument. The performance of the PC does not affect the accuracy of the measurement results, and so there is no need for the either the PC or its software to be covered by a calibration certificate. |