Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter

The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter is a portable bench multimeter suitable for measuring DC voltage, DC current, TRMS AC voltage, TRMS AC current, resistance (2-wire and 4-wire), frequency, capacitance and temperature. It also includes continuity and diode tests and an array of smart/ maths functions, as well as data logging capabilities. The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter has a high accuracy and resolution: 0.02%, 1µV, 1mW, 100nA, 0.01Hz, 10pF.

Bus Interfaces

The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter differs from its sister product, the Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter, in that it includes RS-232, GPIB and LAN (Ethernet) interfaces in addition to a USB interface.

The LAN interface is LXI compliant; this interface along with the RS-232 and GPIB interfaces require AC line power in order to function. The USB interface is powered by the controlling device which means the Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter can be powered by batteries without the USB interface causing additional power drain.

Rechargeable Batteries

To enable testing in remote locations without AC line power, the Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter can be powered by rechargeable batteries for up to thirty-five hours. The batteries are charged by the Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter’s internal power supply.

Dual Display and Dual Measurement

The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter features dual-measurement functionality and is equipped with a dual 5 ½-digit display that can be configured to show any of the following measurement and parameter combinations:

  • The measurement and selected range
  • The measurement in two different units
  • The result of the calculated function: value and % deviation
  • Measurements for two separate parameters of a single signal
  • Measurements for the same parameter for two different signals

Automatic and Manual Ranging

Fast-responding automatic ranging ensures that all measurement parameters are displayed to the best possible resolution. As mentioned above, the Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter’s display can be configured to show the measurement and the selected range; this provides greater clarity.

The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter also supports manual ranging.

Wide True RMS AC Measurements

True-RMS AC measurement capabilities ensure that the Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter is able to provide accurate AC current and voltage readings regardless of the waveform’s shape.

Furthermore, a wide bandwidth attenuator provides high accuracy within the audio band, as well as an extended response that prevents errors when measuring switching waveforms.

Additionally, the Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter includes an option for determining the TRMS value of AC plus DC components, as well as standard AC coupled measurements.

Frequency & Capacitance

The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter includes five capacitance ranges up to 120µF.

The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter is also able to provide high accuracy (better than 0.01%) frequency measurements between 10Hz and 120kHz. The utilisation of a reciprocal counting technique ensures that frequency updates are quick and provides a resolution of up to 0.01Hz.

Temperature Measurement

The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter includes linearised measurement for PT100 and PT1000 platinum resistance temperature detectors (RTDs) and supports 2-wire and 4-wire connections. Temperature measurements can be displayed in °C or °F.

Automatic Data Logging

The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter can store up to five-hundred measurements which can be recalled to the display or downloaded via a remote interface.

The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter can be programmed to log measurements at a rate ranging from one reading per second up to one reading per three hours. Alternatively, the Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter can be configured to log measurements when triggered by an opto-isolated external trigger input or via a digital interface. It includes an external trigger connector on the rear panel to enable external triggering of the Measurement Hold or Measurement Log function. An opto-isolated open collector output is also available for synchronisation with the measurement update.

The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter also includes an option for manual data logging.

Smart Functions

In addition to the aforementioned measurement and data logging capabilities, the Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter includes the following smart/ maths functions.

Linear Scaling with Offset

This function is particularly useful when testing 4-20mA current loops. It scales the electrical output of a transducer to provide a direct readout of a physical parameter such as temperature or weight. The Linear Scaling with Offset function multiplies the reading by a scale factor (A) and either adds or subtracts an offset (B).

dB Measurement

The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter can display AC voltages in dB as well as volts.

Furthermore, the Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter’s integrated zero reference scaling means that AC voltages can be displayed in dBm relative to an impedance value between 50W and 8kW. The voltage is displayed simultaneously on the secondary display.

Limits Comparison

The reading is compared to the user-programmed upper and lower limits and a HI, LO or PASS result is indicated alongside the measurement.

Percentage Deviation (%)

The reading is compared to a user-set nominal value and the percentage by which it deviates from this value is displayed. The Percentage Deviation function can be used to measure tolerance and stability.

Min-Max Storage

The Min-Max Storage function records the highest and lowest values measured over the testing period. This function can be used to record peak temperatures and check for power supply glitches.

Power Measurement in Watts or VA

The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter can measure power in dBs, Watts or VA.

The VA function displays the product of voltage and current by utilising the Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter’s dual measurement capability.

The Watts function calculates V2/R for load resistances between 1W and 10kW. It is particularly useful for audio measurements.

Graphical Interface for PC

The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter is supplied with Aim-TTi’s 1908-PC Link Software. This Windows-based software can be used to operate the Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter remotely via a PC.

The graphical interface displayed on the user’s PC is similar to the menu system on the Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter; this allows the user to set measurement ranges, select measurement functions for the main and secondary displays, and log data quickly and easily. The Aim-TTi 1908-PC Link Software can also be used to download data saved to the Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter’s memory.

Data can be viewed in a table or in an analogue bar graph with minimum and maximum reading markers. It can also be exported to a CSV file.

IVI Driver

Additionally, the Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter includes an IVI driver for Windows that provides support for LabView, LabWindows and Keysight VEE.

Safety and Calibration

Kensington Security Slot

The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter’s rear panel includes a Kensington security slot allowing it to be secured using a Kensington cable system.

Comprehensive Safety Protection

The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter is compliant with EN61010-1 2010 and EN61010-2-030 2010 up to 300V (CAT III), 600V (CAT II) or 1000V DC/ 750V AC (for circuits isolated from AC line). It is also protected against accidental overloads on all ranges including 10A.

Closed-Case Calibration

The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter stores calibration constants in its protected memory which enables closed-case calibration.

The Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter is a portable, high-performing and comprehensive bench DMM.

Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter Key Features

  • A portable bench digital multimeter
  • DC voltage
  • DC current
  • TRMS AC voltage
  • TRMS AC current
  • Resistance (2-wire and 4-wire)
  • Frequency
  • Capacitance
  • Temperature
  • Continuity test
  • Diode test
  • Smart/ maths function
  • Data logging capabilities
  • High accuracy and resolution: 0.02%, 1µV, 1mW, 100nA, 0.01Hz, 10pF
  • Bus interfaces: RS-232, GPIB, LAN and USB
  • LAN interface is LXI compliant
  • LAN, RS-232 and GPIB interfaces must be powered by an AC line
  • USB interface is powered by the controlling device which means the DMM can be powered by batteries without additional power drain
  • Can be powered by an AC line or rechargeable batteries
  • Rechargeable batteries provide up to thirty-five hours of power
  • The batteries can be charged by an internal power supply
  • Dual measurement functionality
  • Dual 5 ½-digit display
  • The dual display can be configured to show a variety of measurement and parameter combinations
  • Fast-responding automatic ranging ensures that all measurement parameters are displayed to the best possible resolution
  • Supports manual ranging
  • True-RMS AC voltage and current measurements provide accurate readings regardless of the waveform’s shape
  • Includes an option for determining the TRMS value of AC plus DC components
  • Five capacitance ranges up to 120µF
  • High accuracy (better than 0.01%) frequency measurements between 10Hz and 120kHz
  • Reciprocal counting technique provides quick frequency updates and a resolution up to 0.01Hz
  • Linearised measurements for PT100 and PT1000 platinum resistance temperature detectors (RTDs)
  • Supports 2-wire and 4-wire connections
  • Temperature measurements can be displayed in °C or °F
  • Store up to 500 measurements
  • View measurements on the display or download them via a remote interface
  • Log readings at a rate ranging from one reading per second to one reading per three hours
  • Data logging can be triggered by an opto-isolated external trigger input or via an external digital interface
  • External trigger connector on the rear panel
  • An opto-isolated open collector output is available
  • Supports manual logging
  • Linear Scaling with Offset function
  • dB Measurement function
  • Limits Comparison function
  • Percentage Deviation (%) function
  • Min-Max Storage function
  • Measure power in dBs, Watts or VA (Watts and VA functions)
  • Supplied with Aim-TTi’s 1908-PC Link Software which enables remote control of the multimeter via a graphical interface on the user’s PC
  • Set measurement functions, parameters and view, log and export data using the Aim-TTi 1908-PC Link Software
  • IVI driver for Windows supports LabView, LabWindows, and Keysight VEE
  • Kensington security slot
  • Compliant with EN61010-1 2010 and EN61010-2-030 2010 up to 300V (CAT III), 600V (CAT II) or 1000V DC/ 750V AC (for circuits isolated from AC line)
  • Closed-case calibration
  • Portable, high-performing and comprehensive bench DMM

What’s Included?

  • Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter
  • Aim-TTi 1908-PC Link Software

Aim-TTi 1908P 5.5-Digit Dual Measurement Digital Multimeter Technical Specifications 

Measurement Parameters & Accuracy
Note Accuracies apply for 1 year 19°C to 25°C. Temperature coefficient outside these limits
is <0.1 x quoted range accuracy per °C.
Scale Length The scale length is 120,000 counts (unless otherwise stated) giving a maximum
measured value for each range of 119999. Thus for the 100V range the maximum
measured value is 119.999 volts
Accuracies are quoted in terms of a percentage of the measured value plus a number
of least significant digits.
Reading Rate Varies with measurement parameter. Selectable as 4 readings/second or 20
readings/second for most parameters.
DCVoltage 
Range Accuracy Resolution
100mV 0.02% ± 3 digits* 1µV
1000mV 0.02% ± 3 digits 10µV
10V 0.02% ± 3 digits 100µV
100V 0.02% ± 3 digits 1mV
1000V 0.02% ± 3 digits 10mV
Note * after null
Typical Input Impedance  10MW//<1000pF, except for Vdc plus Vac measurement when the 1MΩ AC attenuator is in parallel with the 10MΩ DC attenuator.
Maximum Input 1kV DC or AC peak, any range
NMR >60dB at 50/60Hz.
CMR 1kW unbalanced CMR is >90dB at DC/50Hz/60Hz
Recommended max.peak AC + DC voltage while measuring DC voltage
Range 100mV 1000mV 10V 100V 1000V
Max. AC 1.8V 1.8V 18V 180V 1000V
Note The table shows the maximum peak AC (45Hz-50Hz) plus DC voltage that can be
applied without affecting the accuracy of the DC measurement due to overload
clamping. These values only apply when the DC component does not exceed the range
maximum and the analogue 50/60Hz rejection filter is enabled.
AC Voltage (True RMS)
Range Accuracy Resolution
45Hz - 10kHz 10kHz - 30kHz 30kHz - 50kHz
100mV 0.2% ± 150 dig 1.5% ± 200 dig - 1µV
1000mV 0.2% ± 100 dig 0.5% ± 100 dig. 2% ± 200 dig 10µV
10V 0.2% ± 100 dig. 0.5% ± 100 dig 2% ± 200 dig. 100µV
100V 0.2% ± 100 dig 0.5% ± 100 dig 2% ± 200 dig 1mV
750V 0.2% ± 100 dig 0.5% ± 100 dig. 2% ± 200 dig 10mV
Note  Accuracy specifications apply for readings between 10,000 and 120,000 counts.
Maximum crest factor 3 at nominal range maximum.
Input Impedance 1MW//<1000pF
Maximum Input 750V rms, 1000V peak; any range
CMR 1kW Unbalanced CMR is >60dB at DC/50Hz/60Hz
AC + DC Voltage  Total measurement error will not exceed the sum of the separate AC and DC accuracy
specifications plus 10 digits.
Resistance  2-wire or 4-wire measurement
Range Accuracy Resolution
100Ω 0.05% ± 8 digits 1mΩ
1000Ω 0.05% ± 5 digits 10mΩ
10kΩ 0.05% ± 5 digits 100mΩ
100kΩ 0.05% ± 5 digits
1000kΩ 0.3% ± 2 digits 10Ω
10MΩ 0.3% ± 2 digits 100Ω
Maximum Input 1000V DC or AC rms, any range.
Max. O/C Voltage 3.5V
DC Current 
Range Accuracy Resolution 
10mA 0.05% ± 5 digits 100nA
100mA 0.05% ± 5 digits 1µA
1000mA 0.2% ± 5 digits 10µA
10A (<5A) 0.2% ± 5 digits 100µA
10A (>5A) 0.5% ± 10 digits 100µA
Maximum Input mA ranges - 1.6A DC or AC rms, 1000V, fuse protected.
10A range - 10A DC or AC rms, 1000V, fuse protected
Voltage Burden 10mA range - <100mV; 100mA, 1A, 10A ranges - <600mV
AC Current (True RMS)
Range Accuracy (45Hz to 10kHz) Resolution
10mA 0.35% ± 20 digits 100nA
100mA 0.35% ± 20 digits 1µA
1000mA 0.5% ± 20 digits 10µA
10A (<5A) 0.5% ± 20 digits 100µA
10A (>5A) 1% ± 20 digits 100µA
Notes  Accuracy specifications apply for readings between 10,000 and 120,000 counts.
Maximum crest factor = 3 is typically 0.5%
Maximum Input mA ranges - 1.6A DC or AC rms, 1000V, fuse protected.
10A range - 10A DC or AC rms, 1000V, fuse protected.
Voltage Burden 10mA range - <100mV; 100mA, 1A, 10A ranges - <600mV
AC + DC Current  Total measurement error will not exceed the sum of the separate AC and DC accuracy
specifications plus 10 digits.
Frequency 
Range Accuracy Resolution 
100Hz 0.01% ± 1 digit 0.01Hz
1000Hz 0.01% ± 1 digit 0.1Hz
10kHz 0.01% ± 1 digit 1Hz
100kHz 0.01% ± 1 digit 10Hz
Scale Length 12,000 counts
Frequency Range 10Hz to >100kHz
Input sensitivity Better than 30mVrms (100mV range);
better than 10% of range for all other Vac and Iac ranges.
Capacitance 
Range Accuracy  Resolution 
10nF 2% ± 5 digits 10pF
100nF 2% ± 5 digits 100pF
1µF 2% ± 5 digits 1nF
10µF 2% ± 5 digits 10nF
100µF 5% ± 5 digits 100nF
Scale Length 1200 counts
Temperature 
Notes  Linearised measurement for PT100 or PT1000 RTD probes, 2-wire or 4-wire
measurement, display in °C or °F.
N. B. Accuracy specifications apply to multimeter only, they do not account for additional probe accuracy
errors.
RTD Range Accuracy  Resolution 
PT100 -50 to 400°C 0.05% ± 0.5°C 0.1°C
PT1000 -50 to 400°C 0.05% ± 0.5°C 0.1°C
Continuity and Diode Test
Continuity 100W range selected; audible tone sounds for impedance <10W.
Diode Test Test current approximately 1mA; displays voltages up to 1.2V.
Max. O/C Voltage 3.5V
Maximum Input 1000V DC or AC rms, any range.
External Remote Trigger (TTL/ CMOS)
Connection Terminal block on rear panel
Input Input to the LED of an opto-isolator through 1kW resistor.
Apply >+3V to trigger remote input. Max. Voltage 10V.
Output Opto-isolated open collector output, conducts for 250ms on
completion of input trigger. Max. off-state Voltage: 10V.
On state sink current 2mA (typical).
Display
Display Type High contrast backlit transflective LCD.
Main display 5½ digits 17mm high,
Secondary display 6 digits 10mm high
Scale Length 120,000 counts for most measurement parameters
Annunciators LCD annunciators for all ranges, functions and program modes
Overrange Displays OFL if input too large for range
Overflow Displays -Or- if calculated result overflows display.
Computing Functions 
Null (Relative) Ω Null

Stores current reading and subtracts it from future readings.

Additional non-volatile function for nulling test lead resistance.

Hold Reading is frozen
T-Hold (Touch & Hold) Reading is frozen when stable
dB Displays measurement in dBm relative to 600W or other user-entered impedance
AC plus DC The RMS value of the AC plus DC parts of the signal is calculated and displayed.
% Deviation Displays % deviation from entered reference value.
Ax+b Linear scaling of results, with offset.
Limits Reading displayed with HI, LO, or PASS with respect to user-defined high and low limits
Min/Max Minimum and maximum reading stored
Power Calculates V2/R and displays in Watts with respect to a user-defined impedance.
VA Calculates and displays Volts x Amps
Data Logger Manual or automatic storage of 500 measurements. Storage interval 1s to 9999s or at the measurement sample rate, manually from keyboard, or by external triggering.
Digital Interface  Full digital remote control facilities are available through the RS232, LAN, USB and GPIB
interfaces.(AC line power is required for RS232, LAN and GPIB interfaces.)
RS232 Standard 9-pin D-connector. Baud rate 9600.
USB Standard USB 2.0 hardware connection. Host Powered.
LAN Ethernet 100/10base-T hardware connection.
LXI Conformance 1.4 LXI Core 2011.
GPIB Conforms with IEEE488.1 and IEEE488.2.
Remote Command
Processing Time
Typically <100ms.
Software Supplied 
IVI Driver An IVI driver for Windows is supplied.
LV/CVI Driver Full installation for CVI and LabVIEW instrument drivers
USB Driver An installation file is supplied calling a standard Windows* USB driver.
Power Requirements 
AC Input 220V-240V or 110-120V AC ±10%, 50/60Hz, by internal adjustment; 20VA max. Installation Category II.
Batteries Internal rechargeable Nickel Metal Hydride
Battery Life > 20 hours with the backlight enabled. Battery life can be increased to > 35 hours with the backlight disabled.
General
Operating Range +5°C to + 40°C, 20% to 80% RH
Storage Range -20°C to + 60°C
Environmental Indoor use at altitudes up to 2000m, Pollution Degree 2.
Safety and EMC Complies with EN61010-1, EN61010-2-030, EN61010-2-033 & EN61326-1.
Security Kensington security slot incorporated
Size 250(W) x 97(H) x 295(D)mm in bench-top configuration
213.5(W) x 86.5(H) x 269(D)mm (2U/ ½ - rack) in rack mount
format
Weight 3.2kg