Important Note:
There are six versions of this Crowcon Gas-Pro detector available. All models detect the same gases (carbon monoxide, hydrogen sulphide, oxygen and methane).
Using the drop-down box above, you will need to select between whether you want a pumped or non-pumped version of the detector, whether it includes a flow plate or not and whether the unit ships with a power charging lead or a power charging cradle.
The options are as follows (part numbers in bold):
- GPA-0014-EA-A: Non-Pumped, No Flow Plate with Multi-Region Power Lead
- GPB-0014-EA-A: Non-Pumped, with Flow Plate and Multi-Region Power Lead
- GPC-0014-EA-A: Pumped, with Flow Plate and Multi-Region Power Lead
- GPA-0014-EA-C: Non-Pumped, No Flow Plate with Multi-Region Cradle Charger
- GPB-0014-EA-C: Non-Pumped, with Flow Plate and Multi-Region Cradle Charger
- GPC-0014-EA-C: Pumped, with Flow Plate and Multi-Region Cradle Charge
The above models are set to English ATEX as standard, for different regions/ alarm levels please contact our sales team before purchase.
Please see the table below for further details regarding the regions and approvals available.
Region/ Approval | Description |
EA | English ATEX |
NU | American UL |
SA | Spanish ATEX |
GA | German ATEX |
DA | Dutch ATEX |
IA | Italian ATEX |
FA | French ATEX |
BI | Brazilian Portuguese INMETRO |
PA | Polish ATEX |
About the Crowcon GasPro Intrinsically Safe Gas Detector
Safety in confined spaces is essential - with Crowcon's GasPro confined space gas detector, you'll have a fast responding, first-response gas detector that instantly alerts you when hazardous levels of gases are detected.
Crowcon's Gas-Pro is a wearable gas detector that's made for attachment to your clothing - it should be worn at all times when working in hazardous environments and gives up to 14 hours of continuous operation using built-in rechargeable batteries.
This version of the Crowcon Gas-Pro can detect four different gases - it is configured, as standard, for the detection of carbon monoxide (CO), hydrogen sulphide (H2S), oxygen (O2) and methane (CH4).
Protect Yourself with Triple Alarms
The Crowcon Gas-Pro is made to make sure you know about hazardous gas levels - if you're working in a confined space, this fast response could be the difference between safe working and potentially deadly accidents.
Crowcon Gas-Pro units come as standard with three different alarm indictors. If a spike in gas content is detected, the Gas-Pro will:
- Sound An Audible Tone Alarm - 95dB loudness with increase in tone frequency as gas levels rise
- Flash Visual LED Alerts - dual red and blue LEDs flash from all angles
- Begin to Vibrate - you'll be able to feel the Gas-Pro as it detects different gases
Optional Flow Plate
Many versions of the GasPro can include a flow plate - when this is attached to the gas detector, it allows the GasPro to be used for various applications such as manual gas/test calibration, or for manual sampling.
If used with the pumped versions (which include an internal pump) the flow plate makes pre-entry testing easier and allows the GasPro to be worn either in pumped or diffusion modes.
Take a look at the flow plate in action in the video below:
Comfortable, Hands-Free Operation
If you're in a confined space, you're likely to be working with your hands, performing a wide variety of tasks.
Crowcon's GasPro is a completely hands-free gas detector; this unit clips directly onto your clothing and is ideal for completely hands-free, constantly reliable gas monitoring.
The GasPro's backlit LCD screen is positioned at the top of the detector; this ensures you can easily read current findings simply by glancing down at the detector, regardless of what lighting conditions you find yourself working in. The backlight can also be adjusted between red and green display modes.
You can also rely on the GasPro for a long period of time - the rechargeable lithium ion batteries built into the detector give on average 14 hours of operation (non-pumped versions) or 13 hours (pumped versions).
Log Your Findings with Built-in Datalogging Capabilities
The GasPro does more than just monitor and alert you to gas levels - it can also constantly log information in its built-in memory storage!
Up to 125 hours of data can be stored directly on the GasPro at 10 second intervals, giving approximately 45,000 logs of data, ready for download to PC using USB connection.
The GasPro also logs events and can store information on activated alarms, overrange detection, calibration, bump testing, when the unit was switched on/off and the TWA system (which evaluates toxicity over time). Up to 1000 events can be stored directly in the detector's memory.
Intrinsically Safe Design
Crowcon GasPro units are made for use in even the most tough environments, complete with ATEX and other approvals for use in potentially hazardous zones where there's a risk of igniting the atmosphere.
These gas detectors have the following classifications:
- IECEx: Ex d ia IIC T4 Gb Tamb -20oC to +55oC
- ATEX: II 2 G Ex d ia IIC T4 Gb Tamb -20oC to +55oC
- UL: Gas detector use in hazardous locations Class 1, Division 1, Groups A, B, C, and D only as to intrinsic safety INMETRO
The detectors are also made tough with IP65 and IP67 classification for superior protection against water and other common forms of damage.
Optional Accessories
The Crowcon Gas-Pro Four Gas Detector can be purchased with a number of different accessories. Before making your purchase please contact our sales team to add any of the following products to your order.
Product Code | Description |
Gas Pro Sampling Options | |
AC0201 | 1m standard tubing (includes tube insert) (other lengths also available) |
AC0301 | 1m tubing for reactive gases (includes tube insert) |
SS0726 | Exhaust bellows (on outlet for pumped sampling, calibration/gas testing) |
AC0103 | Calibration flow plate for PC Calibration (no magnet) |
M04038 | Gas-Pro flow plate individual gasing |
S013055 | Gas-Pro dust filter flow plate |
Gas-Pro Charging Options | |
CH0100 | Multi-region power lead (includes CH0101 & CH0102) |
CH0101 | Multi-region power supply |
CH0102 | Charging lead |
CH0103 | USB communications lead (not powered) |
CH0104 | USB dual communication and power lead |
CH0105 | Gas-Pro charger cradle (no power) |
CH0106 | Vehicle charging adaptor For use with CH0102 charging lead |
CH0107 | 5 Way multi-region power supply (use with 5 x CH0102) |
Inmerto Certified | |
CH0200 | Multi-region power lead (includes CH0101 and CH0202) - Inmetro |
CH0202 | Charging lead - Inmetro |
CH0203 | USB communications lead (not powered) - Inmetro |
CH0204 | USB communication and power lead - Inmetro |
Gas Pro Accessories | |
AC0500 | Tube insert (connection from tube to flow plate) x10 |
AC0511 | Elbow tube insert x 10 |
AC0502 | Water trap |
AC0504 | Hand aspirator bulb |
AC0506 | Chest harness plate |
AC0507 | Chest harness straps (2 per pack) |
AC0508 | Single strap |
AC0509 | Drop line 6m (includes D-ring clip) |
AC0512 | Ball float probe (select tubing length separately) |
Crowcon GasPro Technical Specifications
Detector Type | Multi-Gas Monitor |
Gasses | O2, CO, H2S and CH4 (Oxygen, Carbon Monoxide, Hydrogen Sulphide and Methane) |
Size (D x L x W) | 43 x 130 x 84mm (1.7 x 5.1 x 3.3") |
Weight | 4 gas (pump) 340g (11.9oz) 4 gas (un pumped) 309g (10.8oz) |
Alarms | Audible>95dB Visual – all angle dual red/blue LEDs Vibrating alert +ve Safety™ |
Display | Top mounted for easy viewing Viewable size 25 x 50mm |
Datalogging | 125 hours @ 10 second intervals (45000 logs) |
Event Logging | Alarm, overrange, calibration, bump, on/off, TWA, 1000 events |
Battery | Rechargeable Li-Ion |
Sampling | Internal pump as option Hand aspirator for non-pumped |
Operating Temperature | -20°C to +55°C |
Storage | -25 to 65°C (-13 to 149°F) |
Humidity | 10 to 95% RH |
Ingress Protection | Independently tested to IP65 and IP67 |
Approvals | IECEx : Ex d ia IIC T4 Gb Tamb -20°C to +55°C ATEX: Ex II 2 G Ex d ia IIC T4 Gb Tamb -20°C to +55°C UL : Gas detector use in hazardous locations Class 1 Division 1 Groups A, B, C and D only as to intrinsic safety |
Compliance | CE, FCC and ICES-003 Complies with EMC directive 2004/108/EC |
Interface | Data connection for use with calibration stations & directly to PC |
Charging Options | Direct connection to multi-region power supply Car charging adapter USB interface cable USB power and communications cable 5-way multi-region power supply |
Reviews
SKU | 0001-EA |
---|---|
Manufacturer Part Code | GPA-0014-EA-A |